A visible fuel leak, a missing filler cap, or an insecure tank fails the annual inspection and meets the out-of-service criteria. This checker applies the rules in 49 CFR 393.65, 393.67, 393.68, 393.69, 392.50, plus 392.51 to the answers you enter. It covers the tank, the lines, the fueling rules, plus reserve fuel carried as materials of trade.

Answer each question from what you can see on the vehicle. Every answer updates the result as you change each field. Leave a question on its first answer when it does not apply to your vehicle.

About the vehicle and the tank

Enter 0 when no liquid fuel tank is fitted, as on a CNG-only vehicle. Tanks over 25 gallons must have a safety venting system. Diesel tanks over 25 gallons must accept fuel at 20 gallons per minute without spilling.

Tank condition: the annual inspection items

Appendix G item 4 lists three fuel-system defects that fail the annual inspection. The same three meet the out-of-service criteria at roadside.

Tank and system location

Fuel lines

Feed, valve, plus fittings

Tank markings and venting

Gas fuel systems, CNG and LPG only

Fueling precautions

Reserve fuel, materials of trade

Enter 0 for a fuel you do not carry. Round each size up to the next whole number. The aggregate counts every material of trade on the vehicle, not just fuel.

Fail: 1 item fails the fuel-system rules.

1 item fails, 1 item needs a closer look, 14 items pass.

The failing items are listed below with the paragraph each one breaks. None of them is an annual-inspection failure under Appendix G item 4, but each one is still a violation of Part 393 or Part 392. Fix them before the next trip.

The checks

CheckResultDetail
Visible fuel leakPassNo visible leak reported. Appendix G item 4a.
Fill pipe capPassCap present plus fastens securely. Appendix G item 4b, section 393.67(c)(7)(v).
Tank mountingPassTank securely attached. Appendix G item 4c, section 393.65(c).
System locationPassNo part extends past the widest point, no tank sits ahead of the front axle, spilled fuel cannot reach the exhaust or electrical system, fill openings sit outside the passenger and cargo compartments. No fuel line runs between vehicles in motion. Section 393.65(b).
Fuel linesFailFails: a diesel crossover, return, or withdrawal line runs below the tank bottom with no impact protection, section 393.65(f).
Gravity or syphon feedPassFuel pump feeds the engine. No gravity or syphon feed to the carburetor or injector, section 393.65(d).
Selection control valvePassOne tank, or no driver-operated valve. Section 393.65(e) does not apply.
Drains and bottom fittingsPassDrains and bottom fittings sit within 3/4 inch of the lowest part of the tank and are impact-protected, section 393.67(c)(4).
Tank certification markingCheckLook for the month and year of manufacture, the maker name, plus the FMCSA certificate on the tank, section 393.67(f).
Capacity markingPassTank plainly marked with its liquid capacity, section 393.67(c)(11).
Safety ventingPassVenting system fitted on a tank over 25 gallons. It must activate before 50 psi, section 393.67(c)(8) and (d)(1)(ii).
Excess-flow deviceNot applicableNo pressure device forces fuel from the tank, so section 393.65(g) does not apply.
CNG containerNot applicableThe vehicle does not run on compressed natural gas, so section 393.68 does not apply.
LPG systemNot applicableThe vehicle does not run on liquefied petroleum gas, so section 393.69 does not apply.
Engine running while fuelingPassEngine off while fueling, section 392.50(a).
Smoking or open flamePassNo smoking or open flame near fueling, section 392.50(b).
Nozzle contactPassNozzle stays in continuous contact with the intake pipe, section 392.50(c).
Reserve gasolinePassLargest gasoline package is 20 L, within the 30 L (8 gallon) limit per package. Packaging is metal or plastic, section 392.51(b) and (c).
Reserve dieselNot applicableNo diesel carried as reserve fuel.
Reserve gas cylinderNot applicableNo Division 2.1 cylinder carried as reserve fuel.
Reserve fuel aggregatePassAggregate gross weight of all materials of trade is 25 kg, within the 200 kg (440 pound) limit, section 392.51(a).

The figures

FigureValueNote
Tank capacity120 gallonsLargest liquid fuel tank capacity entered.
Safety ventingRequiredApplies to liquid fuel tanks over 25 gallons, section 393.67(c)(8).
Diesel fill rate20 gallons per minuteMinimum fill rate without spillage, section 393.67(c)(7)(ii).
Annual inspection fuel items failing0 of 3Appendix G item 4: visible leak, missing filler cap, insecure tank.
Largest gasoline package20 L of 30 L allowedPer package, section 392.51(c).
Largest diesel packageNone carriedPer package limit is 450 L (119 gallons), section 392.51(d).
Gas cylinderNone carriedPer cylinder limit is 100 kg (220 pounds), section 392.51(e).
Aggregate materials of trade25 kg of 200 kg allowed12.5% of the aggregate limit, section 392.51(a).

What to fix

  • Fit impact protection on the diesel crossover, return, plus withdrawal lines that run below the tank bottom, section 393.65(f).

What to record

  • Report any fuel-system defect that affects safe operation on the driver vehicle inspection report, section 396.11(a)(2)(i). Fuel is not in the enumerated list in section 396.11(a)(1), but the report must still list any safety defect the driver finds.
  • Keep the annual inspection report for 14 months from the inspection date, section 396.21(b)(1).

Notes

  • The 95 percent overfill restriction is gone. FMCSA removed section 393.67(c)(12)(i) effective March 23, 2026, in response to a CVSA petition, FR Doc. 2026-03265. Tanks must still pass the section 393.67(d) tests. Normal fuel expansion must still not cause spillage.
  • Appendix G item 4 and the out-of-service criteria treat the fuel system the same way: a visible leak, a missing filler cap, or an insecure tank fails the annual inspection and meets the out-of-service criteria.
  • A vehicle that meets the fuel system integrity requirements of FMVSS 301, 49 CFR 571.301, is exempt from section 393.67 as it applies to the fueling system, section 393.67(a)(7).
  • The ban in section 393.65(d) covers fuel supplied by gravity or syphon feed directly to the carburetor or injector. It does not describe a transfer line that moves fuel from one tank to another.
  • The reserve fuel limits in section 392.51 cover fuel carried as materials of trade. Fuel in the vehicle tanks is not reserve fuel and is not counted against the 200 kg aggregate.

This tool applies 49 CFR 393.65, 393.67, 393.68, 393.69, 392.50, plus 392.51 to your answers. Confirm a failure on the vehicle before ordering parts or booking a repair.

Your inputs stay in this browser. Nothing is sent to our servers. There is no account to create.

Disclaimer: This checker applies the published fuel-system rules to the answers you enter, not legal advice — confirm any failure with a qualified inspector or your safety department before operating the vehicle.

Quick answer: DOT fuel tank requirements sit in 49 CFR 393.65 for all fuel systems plus 393.67 for liquid fuel tanks. A tank must sit inside the widest part of the vehicle, behind the front axle, with a secure cap, secure mounting, plus lines that stay within 2 inches of the tank bottom unless protected. A visible leak, a missing filler cap, or an insecure tank fails the annual inspection under Appendix G item 4. Reserve fuel carried as materials of trade is limited to 200 kg in total under section 392.51. The checker above runs every rule against your answers.

Last reviewed: · Focus keyword: truck fuel tank requirements DOT

What does DOT require for a truck fuel tank?

DOT fuel tank requirements sit in Part 393, Subpart E of the Federal Motor Carrier Safety Regulations, plus two driver rules in Part 392. Section 393.65 covers all fuel systems: where the system may sit, how the tank is attached, how fuel is fed to the engine, how the lines run, plus when an excess-flow device is needed. Section 393.67 covers liquid fuel tanks in detail: construction, fill pipes, venting, markings, plus the tests a tank must pass. Section 393.68 covers compressed natural gas containers. Section 393.69 covers liquefied petroleum gas systems. Sections 392.50 and 392.51 cover the driver side: fueling precautions plus reserve fuel carried as materials of trade.

The rules split into two groups. The first group binds the manufacturer: tank construction, joints, threads, venting, plus the drop and leakage tests. A carrier buys a tank that already meets those rules, then keeps it in that condition. The second group binds the carrier and the driver: mounting, location, line routing, cap condition, plus fueling behavior. The checker above covers the second group in full, plus the construction items a driver or inspector can verify by eye, such as the certification marking and the capacity marking.

The annual inspection is where the rules bite. Every commercial motor vehicle needs a periodic inspection at least once every 12 months under section 396.17, judged against the minimum standards in Appendix G to Subchapter B. Item 4 of that appendix lists three fuel-system defects that fail the inspection outright: a visible leak, a missing filler cap, plus an insecure tank. The appendix comparison states that the fuel-system criteria are the same for the annual inspection and the out-of-service criteria, so the same three defects can put a vehicle out of service at roadside. A carrier that checks the fuel system before the inspection date avoids that outcome.

Two 2026 rule changes shape the current text. FMCSA removed the 95 percent overfill restriction from section 393.67(c)(12) effective March 23, 2026. It added a narrow auxiliary-pump exception to the gravity-feed ban in section 393.65(d) on the same day. Both changes are covered in their own sections below, with the Federal Register citations.

Where can a fuel tank sit on a truck?

Section 393.65(b) sets six location rules. Each one answers a fire question: where fuel can go, what it can touch, plus where it can spill.

First, no part of the system extends beyond the widest part of the vehicle. A tank, line, or fitting that sticks out past the bodywork is exposed to side impact and to roadside strikes. The rule measures the system against the widest part of the vehicle as built, not against mirrors or other add-ons.

Second, no part of a fuel tank is forward of the front axle of a power unit. A tank ahead of the front axle sits in the crush zone of a frontal crash. The rule applies to power units, which covers truck tractors plus straight trucks. A trailer tank follows the other location rules but not this one.

Third, fuel spilled vertically from a fuel tank while it is being filled will not contact any part of the exhaust or electrical systems of the vehicle, except the fuel level indicator assembly. The word vertically matters: the rule tests the straight-down spill path from the fill point, not a splash in any direction. The single exception is the fuel level indicator assembly, which sits in the spill path by design.

Fourth, fill pipe openings are located outside the passenger compartment and its cargo compartment. A fill opening inside a compartment puts fuel vapor where people breathe and where cargo can soak it up. The rule covers both compartments: the cab plus any cargo space.

Fifth, a fuel line does not extend between a towed vehicle and the vehicle that is towing it while the combination of vehicles is in motion. A line bridging two moving units flexes at the coupling with every turn and every bump. The rule bans that arrangement while the combination moves.

Sixth, no part of the fuel system of a bus manufactured on or after January 1, 1973, is located within or above the passenger compartment. Buses carry the strictest location rule because a leak above passengers has the worst outcome. The date line matters: a bus built before 1973 is not covered by this paragraph, though the other five rules still apply.

What makes a fuel tank fail a DOT inspection?

Only three defects appear in the fuel-system item of the annual inspection standard. Appendix G to Subchapter B, item 4, says a vehicle does not pass an inspection if it has one of the following defects or deficiencies: a fuel system with a visible leak at any point; a fuel tank filler cap missing; a fuel tank not securely attached to the motor vehicle by reason of loose, broken, or missing mounting bolts or brackets. The item adds a note: some fuel tanks use springs or rubber bushings to permit movement, so a tank that moves on its mounts is not automatically insecure.

Note the word visible in the leak defect. The inspector does not need a pressure test or a dye check. A leak the inspector can see is enough to fail the vehicle. A damp fitting that has not yet dripped is a judgment call for the inspector, but a carrier that waits for a drip is waiting too long. Any wetness around a tank seam, a fitting, or a line connection deserves a repair before the inspection date.

The cap defect is the cheapest failure on the whole inspection list. A missing filler cap costs a few dollars to replace, yet it fails the vehicle outright. A cap that is present but will not fasten securely is a violation of section 393.67(c)(7)(v) even though Appendix G names only a missing cap. The checker above treats a loose cap as a failure for that reason.

The mounting defect turns on the hardware: loose, broken, or missing mounting bolts or brackets. Straps, bands, plus brackets all count as mounting hardware. Rust that has thinned a bracket to the point of cracking is a broken bracket in substance, even if the pieces still hang together. An inspector who finds a cracked bracket will fail the vehicle.

Failing the annual inspection is not the end of the story. The comparison section at the end of Appendix G states that the fuel-system criteria are the same for Appendix G and the out-of-service criteria. A roadside inspector who finds a visible leak, a missing cap, or an insecure tank can place the vehicle out of service on the spot. The repair then happens at the roadside or at the nearest repair facility, not back at the yard. The Annual Inspection Due-Date Tracker works out when the next inspection falls due, so the fuel-system check can happen before the inspector arrives. A Part 393 violation found at roadside also feeds the vehicle factor of the safety fitness rating, which the Safety Rating Predictor models.

What are the fuel line rules for trucks?

Section 393.65(f) covers fuel lines in one paragraph with two numbered conditions plus two opening sentences. The opening sentences set the measurements. The conditions set the quality standard.

First measurement: a fuel line which is not completely enclosed in a protective housing must not extend more than 2 inches below the fuel tank or its sump. The 2-inch limit applies only to a line that is not enclosed. A line inside a protective housing may run lower, because the housing takes the impact instead of the line. The measurement runs from the bottom of the tank or sump to the lowest point of the line.

Second measurement: diesel fuel crossover, return, or withdrawal lines that extend below the bottom of the tank or sump must be protected against damage from impact. That second sentence is diesel-only. It has no 2-inch allowance. Any diesel line of those three types that runs below the tank bottom needs impact protection, whether it hangs 1 inch or 6 inches below. A guard, a shield, or a housing all count as protection. The checker default shows this failure on purpose: an unprotected diesel line below the tank bottom is the most common fuel-line violation on a working tractor, because the lines are easy to see and easy to ignore.

Then the two conditions. Every fuel line must be long enough and flexible enough to accommodate normal movements of the parts to which it is attached without incurring damage. A line pulled tight across a joint will crack at the fitting. A line with no slack for suspension travel will chafe through at the clamp. Second, every fuel line must be secured against chafing, kinking, or other causes of mechanical damage. Clamps, clips, plus routing all count. A line resting on a sharp frame edge fails even if it has not yet worn through, because the rule asks whether the line is secured against chafing, not whether chafing has already happened.

Is a gravity feed fuel system legal on a truck?

Section 393.65(d) is titled Gravity or syphon feed prohibited. The text is short: a fuel system must not supply fuel by gravity or syphon feed directly to the carburetor or injector. The two words that decide most cases are directly and to. The ban covers fuel fed straight to the carburetor or injector by gravity or syphon action, with no pump in between. A transfer line that moves fuel from one tank to another is not feed directly to the carburetor or injector, so it is not what this paragraph bans. The distinction matters for auxiliary in-bed tanks: a gravity transfer into the main tank leaves the factory pump and injection system in charge of delivery to the engine.

The reason for the ban is fire. A gravity-fed line keeps flowing after a crash or a line break, because nothing shuts it off. A pump-fed line stops when the pump stops. FMCSA said so in the 2026 rulemaking: the prohibition is primarily intended to prevent the continuous fueling of any fires that may occur.

The 2026 change added the only exception. Effective March 23, 2026, section 393.65(d) permits gravity or syphon feed when an auxiliary pump with a nominal fuel tank capacity of not more than 5 gallons is mounted on the trailer chassis frame or trailer bed for purposes other than operation of the motor vehicle. The auxiliary pump is operated only when the motor vehicle is not in motion. The exception came from a Truck Trailer Manufacturers Association petition: small trailer-mounted pumps for equipment such as liftgates and reefers, used only while parked, presented no moving-vehicle fire risk. Every condition must hold at once: 5 gallons or less, trailer-mounted, non-propulsion purpose, plus stationary operation. A 6-gallon tank, a pump mounted on the tractor, or a pump run while driving all fall outside the exception.

One loose end closed in July 2026. Charles Machine Works had held a five-year exemption from section 393.65(d) for gravity-fed auxiliary equipment, granted in September 2020. FMCSA withdrew the exemption renewal proceeding on July 30, 2026, because the new exception already covered the equipment. No exemption is needed now for a setup inside the exception. No exemption can authorize a setup outside it.

Is the 95 percent fuel tank rule still in force?

No. FMCSA removed it effective March 23, 2026.

The old rule sat in section 393.67(c)(12)(i). It required a liquid fuel tank manufactured on or after January 1, 1973, to be designed and constructed so that it could not be filled, in a normal filling operation, with a quantity of fuel exceeding 95 percent of the tank liquid capacity. A companion sentence required a warning marking on the tank. The provision dated to 1971 and rested on the Motor Carrier Safety Act of 1935.

The Commercial Vehicle Safety Alliance petitioned for removal. CVSA argued the limit was unnecessary and outdated: modern tanks, modern fill practices, plus the safety venting and leakage tests in section 393.67(d) already control the expansion risk the 95 percent limit was meant to address. FMCSA agreed and published the final rule on February 19, 2026, as FR Doc. 2026-03265, docket FMCSA-2025-0117, effective March 23, 2026.

What remains: section 393.67(c)(12) still exists, but it now reads as a single sentence: a liquid fuel tank manufactured on or after January 1, 1973, must be designed and constructed so that when the tank is filled, normal expansion of the fuel will not cause fuel spillage. FMCSA also stated that removing the 95 percent limit does not require tanks to allow 100 percent fill. Tanks must still pass the safety venting and leakage tests in section 393.67(d).

For a driver or carrier, the practical change is small. No inspector measures a fill percentage at roadside. No carrier was ever cited for filling past 95 percent in normal operation. The change matters most to tank makers, who no longer need to design a fill limit into the tank. Old training material that still quotes the 95 percent rule is out of date: check the current text of section 393.67(c)(12) before relying on it.

What must a liquid fuel tank be built to?

Section 393.67 is a construction standard first and an inspection standard second. Most of its paragraphs bind the tank maker, not the carrier. A carrier meets the section by buying a certified tank and keeping it in its certified condition. The paragraphs a driver or inspector can verify by eye are the markings, the cap, the drains, plus the visible condition of the tank body.

RequirementWhat the rule saysParagraph
JointsClosed by welding, brazing, silver soldering, or equal methods. Never closed by crimping alone or by lead-based soft solder.(c)(1)
FittingsFlanges or spuds suitable for all fittings. Threads Dryseal taper pipe thread, at least four full threads engaged.(c)(2), (c)(3)
Drains and bottom fittingsExtend no more than 3/4 inch below the lowest part of the tank or sump. Protected against impact. Must permit substantially complete drainage.(c)(4)
Withdrawal fittingsAbove the normal fuel level when the tank is full, except on diesel tanks.(c)(5)
Fill pipeDesigned to minimize spillage during fueling plus in a crash. Diesel tanks over 25 gallons must accept fuel at 20 gallons per minute without spillage. Cap fastens securely.(c)(7)
Safety ventingTanks over 25 gallons must have a venting system that prevents rupture in a fire. Activates before 50 psi.(c)(8), (d)(1)
Pressure resistanceBody and fittings withstand 150 percent of the maximum pressure reached in the venting test.(c)(9)
Air ventNonspill air vent on every tank, such as a ball check. May combine with the cap or safety vent.(c)(10)
MarkingsVisible tank plainly marked with liquid capacity.(c)(11)
CertificationMonth and year of manufacture, maker name, plus the FMCSA certificate wording.(f)

Two performance tests back the construction rules. The safety venting test fills the tank three-fourths full, seals the feed outlet, inverts the tank, then applies an enveloping flame so the fuel temperature rises 6 to 8 degrees Fahrenheit per minute. The venting system must activate before the internal pressure exceeds 50 pounds per square inch, gauge. The pressure must not then rise more than 5 psi above the activation pressure. The leakage test fills the tank to capacity with the cap installed, then turns the tank through 150 degrees in any direction: neither the tank nor any fitting may leak more than 1 ounce of fuel per minute in any position.

Side-mounted tanks face two more tests. A side-mounted tank is one that extends outboard of the vehicle frame and outside the plan view outline of the cab on a truck tractor, or outboard of a line tangent to the outboard side of a front tire on a truck. The fill pipe does not count as part of the tank for this test. The drop test fills the tank with water equal in weight to the maximum fuel load and drops it 30 feet onto an unyielding surface, landing squarely on one corner. The fill-pipe test drops the same loaded tank 10 feet onto its fill pipe. In each test, leakage must not exceed 1 ounce of water per minute.

The certification marking is the item a carrier can check without tools. Each liquid fuel tank must be legibly and permanently marked by the manufacturer with the month and year of manufacture, the maker name on tanks made on and after July 1, 1989, plus a certificate in one of two set forms: Meets all FMCSA side-mounted tank requirements, or Meets all FMCSA requirements for non-side-mounted fuel tanks. A tank without those markings may predate the marking rule or may never have met the section. Either way, the checker flags it for a closer look.

Old tanks follow a shorter list. A liquid fuel tank manufactured on or after January 1, 1973, must meet all the rules in the section, as must any side-mounted gasoline tank regardless of date. A diesel tank built before 1973 and mounted on a bus must meet the fill-pipe paragraph (c)(7)(ii) plus the leakage test (d)(2). A diesel tank built before 1973 and mounted on any other vehicle must meet (c)(7)(ii) only. A gasoline tank built before 1973, other than a side-mounted tank, must meet (c)(1) through (c)(10), plus (d)(2) when mounted on a bus. A vehicle that meets the fuel system integrity requirements of FMVSS 301 is exempt from the section as it applies to the fueling system.

What are the rules for CNG and LPG fuel systems?

Compressed natural gas and liquefied petroleum gas each get one short section. Both sections point outward to another standard instead of writing their own construction rules.

CNG runs under section 393.68. Any motor vehicle manufactured on or after March 26, 1995 that is equipped with a CNG fuel tank must meet the CNG container requirements of FMVSS No. 304 in effect at the time of manufacture of the vehicle. Note the trigger: the vehicle build date, not the container build date. Each CNG fuel container must be permanently labeled in accordance with FMVSS No. 304, S7.4. The label rule has no date limit: it applies to each container. A container with a missing or unreadable label fails the section even on an older vehicle.

LPG runs under section 393.69. An LPG fuel system must conform to the Standards for the Storage and Handling of Liquefied Petroleum Gases of the National Fire Protection Association, with the edition set by the installation date.

System installedEdition that applies
Before December 31, 19621951 edition
December 31, 1962 to December 31, 1972Division IV of the June 1959 edition
On or after January 1, 1973, propulsionDivision IV of the 1969 edition
On or after January 1, 1973, auxiliary equipmentDivision VII of the 1969 edition

A system may conform to a later edition instead of the edition its date names. The tank must be marked to indicate that the system conforms to the Standards. That marking is the item the checker asks about: a tank with no NFPA 58 conformance marking fails the section on its face.

Both gas systems still follow section 393.65, which covers all fuel systems regardless of fuel type. Location, mounting, lines, plus the gravity-feed ban apply to a CNG or LPG system the same way they apply to a diesel system. Section 393.67 does not apply: it covers liquid fuel tanks. Neither CNG nor LPG is a liquid fuel at normal temperatures and pressures. The checker above applies the liquid-tank rows only when the fuel is diesel or gasoline.

What are the fueling precautions under section 392.50?

Section 392.50 is four short prohibitions. All four bind the driver plus any employee of the motor carrier.

First, do not fuel a commercial motor vehicle with the engine running, except when it is necessary to run the engine to fuel the commercial motor vehicle. The exception is narrow: it covers a vehicle that cannot be fueled with the engine off, not a driver who prefers to keep the engine running. Most trucks fuel normally with the engine off.

Second, do not smoke or expose any open flame in the vicinity of a commercial motor vehicle being fueled. Vicinity is not defined by distance in the rule. A cigarette at the next pump is plainly in the vicinity. The safe reading is the whole fuel island.

Third, do not fuel a commercial motor vehicle unless the nozzle of the fuel hose is continuously in contact with the intake pipe of the fuel tank. Continuous contact bleeds off static charge. A nozzle held clear of the fill pipe while fuel flows is a static spark waiting for vapor.

Fourth, do not permit, insofar as practicable, any other person to engage in such activities as would be likely to result in fire or explosion. The driver is responsible for bystanders too, as far as practicable. A passenger lighting a cigarette beside a fueling truck is the driver problem to stop.

Fueling precautions pair with emergency equipment. A working fire extinguisher is the last line of defense when a precaution fails. The Emergency Equipment Checker covers the extinguisher rules for the vehicle.

How much reserve fuel can a truck carry?

Section 392.51 lets a carrier designate small amounts of fuel as materials of trade. Materials of trade is a hazardous materials term defined in section 171.8: hazardous materials carried by a private carrier in direct support of its principal business, not for hire. Fuel for the operation or maintenance of a commercial motor vehicle, including its auxiliary equipment, qualifies.

The limits are per package plus one aggregate.

What is limitedLimitParagraph
Aggregate gross weight, all materials of trade200 kg (440 pounds)(a)
Gasoline package30 kg (66 pounds) or 30 L (8 gallons)(c)
Diesel package450 L (119 gallons)(d)
Division 2.1 gas cylinder100 kg (220 pounds) gross weight(e)

Read the gasoline limit carefully: 30 kg or 30 L, either measure. A package within either measure passes. A standard 5-gallon can holds about 19 liters, well within the limit. A 10-gallon can holds about 38 liters and fails the liter measure. The diesel limit is far more generous at 450 liters, because diesel is a combustible liquid with a higher flash point than gasoline. The cylinder limit covers LPG, butane, propane, liquefied natural gas, plus methane: any Division 2.1 flammable gas in a cylinder.

Gasoline packaging has its own rule. Packaging for gasoline must be made of metal or plastic and conform to the hazardous materials rules in Parts 171, 172, 173, plus 178, or to the OSHA rules in 29 CFR 1910.106. A glass jar, a bucket, or an open container fails regardless of size.

The aggregate is the limit drivers miss most often. The 200 kg cap covers all materials of trade on the vehicle, not just fuel. Cleaning solvents, aerosols, adhesives, plus any other hazardous material carried for the business all count toward the same 200 kg. Fuel in the vehicle tanks does not count: it is not reserve fuel. It is not materials of trade.

Fuel bought for the road tanks still counts in the quarterly IFTA return, even when it is bought outside the base jurisdiction. The IFTA Fuel Tax Estimator works out the quarterly fuel tax from miles plus gallons purchased.

Does a fuel leak go on the DVIR?

Yes, when the defect affects safe operation. The answer turns on two paragraphs of section 396.11 that drivers often read separately.

Paragraph (a)(1) lists the parts and accessories the daily report must cover: service brakes, parking brake, steering mechanism, lighting devices and reflectors, tires, horn, windshield wipers, rear vision mirrors, coupling devices, wheels and rims, plus emergency equipment. Fuel is not in that list. A driver who reads only the list could conclude that a fuel defect never belongs on the report.

Paragraph (a)(2)(i) closes that gap. The report must identify the vehicle and list any defect or deficiency discovered by or reported to the driver which would affect the safety of operation of the vehicle or result in its mechanical breakdown. A fuel leak affects safe operation by any measure: it is a fire risk, a slip risk, plus an out-of-service defect. It belongs on the report even though fuel is not in the (a)(1) list. The same logic covers any fuel-system defect the checker flags as a failure.

Once listed, the defect triggers the repair rule in paragraph (a)(3). Before the carrier requires or permits a driver to operate the vehicle again, the carrier must repair any listed defect likely to affect safe operation, then certify on the report that the defect was repaired or that repair is unnecessary. The carrier keeps the report plus the repair certification for three months from the date the report was prepared, under paragraph (a)(4). The DVIR Checker covers the report rules in full. The DOT Record Retention Checker works out how long each record in the file must be kept.

How do you use the Fuel System, Tank and Fueling Checker?

Work through the fields in order. The tool updates with every change, so you can fix an answer and watch the verdict change.

  1. Pick the fuel, the vehicle type, the tank build date, plus the tank capacity.
  2. Answer the tank condition questions: leak, cap, plus mounting.
  3. Answer the location, line, feed, valve, plus marking questions.
  4. Answer the fueling questions, then enter the reserve fuel quantities.
  5. Read the verdict, the checks table, plus the figures.
  6. Copy the summary for the safety file, then fix the failed items before the next trip.

Answer from the vehicle, not from memory. Walk around the tank with the checker open: look at the cap, the mounting brackets, the lines below the tank, plus the markings on the tank body. A check done from the cab misses the items that fail inspections. When an answer is uncertain, pick the answer that describes the worst case you can see, then confirm it on the vehicle before ordering parts.

Read the fix list before the notes. It names each failed item with the paragraph it breaks, in the same order as the checks table. The notes explain the rules behind the verdict: the removed 95 percent rule, the Appendix G and out-of-service link, plus the FMVSS 301 exemption. The What to record section lists the DVIR and inspection-report duties that follow from the result.

Questions drivers ask

What is the DOT rule for fuel tank location?

Section 393.65(b) sets six location rules: no part of the system beyond the widest part of the vehicle, no tank forward of the front axle of a power unit, spilled fuel must not contact the exhaust or electrical systems, fill openings outside the passenger and cargo compartments, no fuel line between towed and towing vehicles in motion, plus no part of the fuel system within or above the passenger compartment of a bus built on or after January 1, 1973.

Can a fuel leak put a truck out of service?

Yes. Appendix G item 4 lists a visible fuel leak as a defect that fails the annual inspection. The appendix comparison states the fuel-system criteria are the same for the annual inspection and the out-of-service criteria. A missing filler cap plus an insecure tank carry the same double effect.

Is the 95 percent fuel tank fill rule still in effect?

No. FMCSA removed the 95 percent limit from section 393.67(c)(12)(i) effective March 23, 2026, in FR Doc. 2026-03265, in response to a CVSA petition. Tanks must still pass the section 393.67(d) tests. Normal fuel expansion must still not cause spillage.

Are gravity feed fuel systems legal on trucks?

Not as a feed to the engine. Section 393.65(d) bans gravity or syphon feed directly to the carburetor or injector. The only exception, added March 23, 2026, covers an auxiliary pump of not more than 5 gallons on a trailer chassis frame or trailer bed, used only while the vehicle is not in motion.

How much reserve fuel can a truck carry?

As materials of trade under section 392.51: gasoline up to 30 kg or 30 L per package in metal or plastic packaging, diesel up to 450 L per package, a Division 2.1 gas cylinder up to 100 kg gross weight, plus an aggregate limit of 200 kg for all materials of trade on the vehicle.

What size fuel tank needs a safety venting system?

A liquid fuel tank with a capacity of more than 25 gallons must have a venting system that keeps fire pressure from rupturing the tank, under section 393.67(c)(8). The system must activate before the internal pressure exceeds 50 psi. The pressure must not then rise more than 5 psi, under section 393.67(d)(1)(ii).