Check before you roll. Section 392.8 bars driving unless the 393.95 equipment is in place and ready for use. A missing extinguisher or a short warning device set is a roadside violation.
Answer for one power unit and one stop. Every answer updates as you change each field.
Your vehicle and cargo
The extinguisher rule turns on placarded hazmat. The flame ban turns on cargo type and fuel. A cargo tank for Class 3 or Division 2.1 counts whether it is loaded or empty.
Fire extinguisher
Rating alone is not enough. Section 393.95(a) also requires the UL label, a gauge that shows a full charge, a filled extinguisher, ready access, secure mounting and a non-freezing agent.
Warning devices
Triangles or fusees, not both together: 3 FMVSS 125 triangles or at least 6 fusees. Red flags are extra equipment and never a substitute for the required devices.
Your stop
Placement distances come from 392.22. The 10-minute clock starts when you stop, not when you start placing devices.
Ready to roll
Your extinguisher and warning devices meet 49 CFR 393.95 on the facts you entered. Place the devices within 10 minutes if you stop on a highway or shoulder.
The checks
| Check | Result | Detail |
|---|---|---|
| Fire extinguisher rating | Pass | You carry one 5 B:C extinguisher. Required: one extinguisher rated 5 B:C or more, or two extinguishers each rated 4 B:C or more. |
| Fire extinguisher condition | Pass | Label, gauge, fill, access and mounting all check out. The agent needs no protection from freezing. |
| Warning devices | Pass | You carry 3 triangles. Three bidirectional reflective triangles meeting FMVSS 125 satisfy 393.95(f)(1). |
| Flame-producing devices | None carried | No flame-producing devices are carried. |
| Placement readiness | Ready | Your warning devices cover the placement pattern below. |
Placement steps
- Activate the hazard warning flashers immediately. Keep them flashing until the warning devices are placed. Use them again while you pick the devices up for storage.
- Place one device on the traffic side, 10 feet from the vehicle toward approaching traffic.
- Place one device 100 feet behind the vehicle, toward approaching traffic, in the center of the lane or shoulder the vehicle occupies.
- Place one device 100 feet ahead of the vehicle, away from approaching traffic, in the center of the lane or shoulder the vehicle occupies.
The 10-minute clock
| Deadline | When | Status |
|---|---|---|
| Warning devices due | Enter your stop time above | Within 10 minutes of the stop |
| Hazard flashers | Immediately at the stop | On until devices are placed |
Notes
- Spare fuses and liquid-burning flares are no longer required equipment. Spare fuses were removed effective 20 April 2026 (91 FR 7877). Liquid-burning flares were removed effective 23 March 2026 (91 FR 7867).
This checker applies 49 CFR 393.95, 392.22, 392.24, 392.25 and 392.8 to your answers. It is not legal advice. Confirm the extinguisher label and the device count on the vehicle before you rely on a result.
Your inputs stay in this browser. Nothing is sent to our servers. There is no account to create.
Disclaimer: This tool is provided for general information only. It is not legal advice โ check the current regulation and your company policy before you rely on a result.
Quick answer: Every truck, truck tractor and bus must carry a fire extinguisher and warning devices under 49 CFR 393.95. A unit that is not hauling placarded hazmat needs one extinguisher rated 5 B:C or more, or two rated 4 B:C or more. A placarded hazmat unit needs one rated 10 B:C or more. Warning devices are 3 reflective triangles meeting FMVSS 125, or at least 6 fusees. If you stop on a highway or shoulder, switch the hazard flashers on at once and place the devices within 10 minutes.
What emergency equipment must a truck carry?
Section 393.95 sets the emergency equipment that every truck, truck tractor and bus must carry. The rule covers two items: a fire extinguisher and warning devices for a stopped vehicle. It applies to the power unit, not the trailer. A unit towed in a driveaway-towaway operation is outside the rule. The driven unit in that operation is excused from the extinguisher part only.
The extinguisher rating turns on hazmat. A power unit hauling placarded hazmat needs one extinguisher rated 10 B:C or more. Any other power unit needs one rated 5 B:C or more, or two each rated 4 B:C or more. The warning device rule offers a choice: 3 bidirectional reflective triangles that meet FMVSS 125, or at least 6 fusees.
Two items left the rule in 2026. Spare fuses were removed effective 20 April 2026. Liquid-burning flares were removed effective 23 March 2026. An old checklist that still lists either item is out of date. The checker above applies the current rule, with both removals built in.
Section 392.8 adds a duty on the driver. No commercial motor vehicle may be driven unless the driver is satisfied that the 393.95 equipment is in place and ready for use. The driver must also use the equipment when it is needed. A pre-trip check that skips the extinguisher gauge and the triangle box leaves that duty unmet. Make the extinguisher and the triangle box part of your pre-trip inspection checklist.
What fire extinguisher rating does a truck need?
The rating is a UL rating. The letters B:C describe the fire classes the extinguisher handles: B for flammable liquids and C for energized electrical equipment. The number is the size rating. A higher number means more extinguishing power. Section 393.95(a)(1) sets the minimum by hazmat status, not by truck size.
A power unit used to transport hazardous materials in a quantity that requires placarding needs one extinguisher rated 10 B:C or more. The placard test comes from 49 CFR 177.823. If your load needs placards, the 10 B:C rule applies. Our hazmat placard checker works out whether a load needs placards.
Any other power unit has two ways to comply. Carry one extinguisher rated 5 B:C or more. Or carry two extinguishers, each rated 4 B:C or more. Two small extinguishers do not add up: two 2 B:C units fail the rule even though the numbers sum to 4. Each unit in the pair must reach 4 B:C on its own.
A load below the placard quantity sits in a gray area in the text. Section 393.95(a)(1)(i) covers placarded quantities. Section 393.95(a)(1)(ii) covers a power unit not used to transport hazardous materials. This checker applies the 5 B:C rule to a below-placard load, which is the reading fleets use in practice. When in doubt, the 10 B:C unit covers every case.
| Power unit | Minimum extinguisher |
|---|---|
| Not hauling hazmat | One 5 B:C, or two 4 B:C |
| Placarded hazmat | One 10 B:C |
| Driven unit, driveaway-towaway | None required |
| Towed unit, driveaway-towaway | Rule does not apply |
What condition must the fire extinguisher be in?
A compliant rating is only the start. Section 393.95(a)(2) through (a)(5) set five more conditions. An inspector can write a violation for any one of them. The extinguisher must carry its UL rating label or marking from the manufacturer. A label that is missing or unreadable fails the rule even when the extinguisher itself is sound.
The extinguisher must let the driver see whether it is fully charged. In practice that means a readable pressure gauge in the green zone, or another visual indicator the design provides. A gauge in the red, a broken gauge glass or a missing pin seal all point the same way. The extinguisher must also be filled, not partly discharged from an earlier use.
Location and mounting matter as much as the gauge. The extinguisher must sit where the driver can reach it at once, not buried under freight or locked in a side box. It must be securely mounted so it cannot slide, roll or move vertically while the truck is moving. A loose extinguisher in the cab is a violation and a hazard in a hard stop.
The agent has its own rule. It must not need protection from freezing, so a water-based unit fails in cold weather service. It must also meet the toxicity provisions of the EPA Significant New Alternatives Policy rules in 40 CFR Part 82, Subpart G. Most modern dry chemical and clean agent units meet both tests. Check the label if the unit is old or unmarked.
What warning devices must a truck carry?
Section 393.95(f) gives the driver a choice of two options. Carry 3 bidirectional emergency reflective triangles that conform to FMVSS 125. Or carry at least 6 fusees, plus as many extra fusees as 392.22 placement requires. Either option satisfies the rule on its own. Carrying both is allowed and common.
Triangles are the practical choice for most drivers. They work in daylight and at night. They need no flame and they never run out. The rule requires bidirectional triangles, which reflect from both directions. A cheap one-way reflector or a single triangle does not meet the standard. Check that the kit holds 3 triangles and that the reflective faces are clean and undamaged.
Fusees are the flame option. Each fusee must burn for 30 minutes and conform to UL 912, Highway Emergency Signals. Each one must carry the UL symbol. Six is the floor, not a safe stock level: a long stop can burn through several fusees, since 392.22 requires a lighted fusee at each of the 3 placement points for as long as the vehicle is stopped.
Red flags sit outside the required options. Section 393.95(k) sets the flag standard at 12 inches square, with a standard that holds the flag upright. Flags may be carried in addition to triangles or fusees. They never replace them. A driver who carries flags alone is short of the rule.
When are fusees and flame devices prohibited?
Flame and flammable cargo do not mix. Section 393.95(g) bars fusees and any other flame-producing signal from three kinds of vehicle. The first is any vehicle transporting Division 1.1, 1.2 or 1.3 explosives. The second is a cargo tank motor vehicle used for Division 2.1 flammable gas or Class 3 flammable liquid, whether the tank is loaded or empty. The third is any vehicle using compressed gas as motor fuel.
The cargo tank rule catches drivers by surprise. An empty tank still counts, because vapor remains after the liquid is offloaded. The ban covers the vehicle, not the load state. A driver who drops a Class 3 load and deadheads home in the same tank unit still may not carry fusees.
Section 392.25 repeats the ban at the point of use and names the substitutes: emergency reflective triangles, red electric lanterns or red emergency reflectors, placed the same way 392.22 prescribes. Section 392.24 adds a separate ban that covers every vehicle: no driver may attach a lighted fusee or any flame-producing signal to any part of a commercial motor vehicle.
Class 3 or Division 2.1 in drums, totes or other packaging is different. The 393.95(g) ban names cargo tank motor vehicles only. Fusees stay legal on a dry van load of paint cans or aerosol cases. The leak rule still applies: if flammable liquid or gas leaks, no flame signal may be lighted near the leak.
The cargo types in the flame ban overlap the list of vehicles that must stop at railroad crossings. A driver hauling explosives or a placarded cargo tank should know both rules before the trip starts. Our railroad crossing stop checker covers the stop rule.
Where do you place warning triangles when stopped?
Section 392.22 sets the pattern. On a two-way road, place 3 devices. The first goes on the traffic side of the vehicle, 10 feet toward approaching traffic. The second goes 100 feet behind the vehicle, toward approaching traffic, in the center of the lane or shoulder the vehicle occupies. The third goes 100 feet ahead of the vehicle, away from approaching traffic, in the same lane or shoulder.
The distances are written in paces in the regulation: 4 paces for the near device and 40 paces for the far devices. The regulation gives the metric and feet equivalents in the same text, about 3 meters or 10 feet and about 30 meters or 100 feet. A pace is a normal walking step, so the distances are easy to judge on foot.
The pattern protects both directions of traffic. The near device warns drivers who are about to pass the truck. The far device behind warns drivers approaching from the rear. The device ahead warns drivers coming the other way. Skipping the forward device is a common error on two-way roads.
Keep the hazard flashers working: they run until the devices are placed. A lighting and reflector check catches a dead flasher before it matters on the shoulder.
| Stop | Device 1 | Device 2 | Device 3 |
|---|---|---|---|
| Two-way road | 10 ft, traffic side | 100 ft behind | 100 ft ahead |
| Divided or one-way road | Within 10 ft of rear | 100 ft toward traffic | 200 ft toward traffic |
| Near hill or curve | 10 ft, traffic side | 100 to 500 ft past the obstruction | 100 ft ahead |
How does placement change on a divided or one-way road?
On a divided or one-way highway, all traffic approaches from one direction, so all 3 devices face that way. Section 392.22(b)(2)(v) sets the pattern: one device on the traffic side within 10 feet of the rear of the vehicle, one device 100 feet toward approaching traffic. The third device goes 200 feet toward approaching traffic. The 100-foot and 200-foot devices sit in the center of the lane or shoulder the vehicle occupies.
The 200-foot device is the one drivers forget. On a two-way road the third device goes ahead of the truck. On a divided road it goes 200 feet back, doubling the warning distance behind. A driver who places the two-way pattern on an interstate leaves the long approach unwarned.
How does placement change near a hill or curve?
A hill crest, a curve or another obstruction to view shortens the sight distance, so the rule stretches the far device. Section 392.22(b)(2)(iv) applies when the vehicle stops within 500 feet of a curve, the crest of a hill or another obstruction. The driver must place the warning signal in the direction of the obstruction at a distance of 100 to 500 feet from the stopped vehicle, far enough to give approaching drivers ample warning.
The 100-to-500-foot band is a judgment call, not a fixed number. Place the device where an approaching driver first gains a clear view of the road ahead. Go no closer than 100 feet. On a sharp curve that may mean the full 500 feet. The checker above asks about hills and curves so the pattern it shows matches the stop.
Are warning devices required in town?
Not always. Section 392.22(b)(2)(iii) excuses warning device placement within the business or residential district of a municipality. The exception has a night condition: it falls away during the time lighted lamps are required, when street or highway lighting is too poor to make the vehicle clearly discernible at 500 feet.
In practice, a daytime stop on a lit city street needs no devices. A night stop on a dark stretch of the same street does. The test is visibility at 500 feet, not the district line. When the lighting is doubtful, place the devices. The cost of placing them is minutes. The cost of skipping them is a rear-end collision.
What is the 10-minute rule for warning devices?
Section 392.22(b)(1) sets the clock. Place the warning devices as soon as possible. The outside limit is 10 minutes from the stop. The clock starts when the vehicle stops, not when the driver gets out or finds the triangle box. Ten minutes is the limit, not a target.
The hazard flashers have no grace period at all. Section 392.22(a) requires the driver to activate the flashers immediately when the vehicle stops on the traveled portion of a highway or the shoulder for any cause other than a necessary traffic stop. The flashers stay on until the devices are placed. They go on again while the driver picks the devices up for storage before moving.
Fusees add a running duty. Section 392.22(b)(2)(i) requires at least one lighted fusee at each of the 3 locations for as long as the vehicle is stopped. A fusee that burns out must be replaced. Before the vehicle moves, the driver must extinguish and remove each fusee. If the stop follows a crash, the testing clock starts too: the post-accident testing checker covers the 2-hour, 8-hour and 32-hour deadlines.
Do trucks still need spare fuses?
No. FMCSA removed the spare fuse rule effective 20 April 2026. The final rule is 91 FR 7877, published 19 February 2026. Section 393.95(b) now reads Reserved. A truck no longer needs one spare fuse for each type and size of fuse the vehicle uses.
The rule had become a paperwork trap. FMCSA counted about 9,000 roadside violations a year for missing spare fuses over the four years before the change. Most modern trucks use blade fuses that rarely fail. A roadside fuse swap seldom fixes the fault that blew the fuse. The agency called the requirement unnecessary and removed it.
Old checklists still list spare fuses. Some inspectors wrote the violation after the removal date. FMCSA safety data still showed rows coded 39395B with inspection dates on or after 20 April 2026. A citation written after the removal date is worth challenging through DataQs.
Carrying spare fuses is still good practice. The rule change removes a federal requirement, not a good idea. A spare fuse kit costs little and can save a service call. It is now a choice, not a duty.
Do trucks still need liquid-burning flares?
No. FMCSA removed the references to liquid-burning flares effective 23 March 2026. The final rule is 91 FR 7867, published 19 February 2026. The change touched 393.95(f)(2), (g) and (j) and 392.22. The agency said the devices are no longer used. The outdated language had to go.
The removal does not touch fusees. A fusee is a self-contained pyrotechnic signal, not a liquid-burning flare. Fusees stay a lawful warning device option under 393.95(f)(2), with the 30-minute burn and UL 912 requirements intact. The two devices are easy to confuse in an old manual. The rule now names fusees only.
The warning device choice is now simple: 3 FMVSS 125 triangles or at least 6 fusees. Any checklist, training slide or handbook that still lists liquid-burning flares as a third option is out of date. Update the document and the kit list together.
What happens if emergency equipment is missing at inspection?
Section 392.8 makes the driver responsible before the truck moves. No commercial motor vehicle may be driven unless the driver is satisfied that the 393.95 equipment is in place and ready for use. An inspector who finds a missing extinguisher, a discharged gauge or a short triangle set writes a violation against the carrier record.
The violation lands on the carrier safety record and feeds the CSA scores that enforcement uses to pick trucks for inspection. A single equipment violation is a small item on its own. A pattern of equipment violations across a fleet signals a maintenance program that is not working. Our CSA violation points checker shows the severity weight and the fall-off date for any violation.
The fine exposure depends on the violation and the enforcement path. FMCSA civil penalties run to thousands of dollars for a serious pattern. A roadside citation can carry its own state fine. Our FMCSA fine calculator shows the maximum federal fine for a violation.
The fix is cheap. A 5 B:C extinguisher, a triangle kit and a monthly gauge check cost less than one roadside delay. Build the extinguisher and the triangle box into the daily pre-trip routine so the check happens before the inspector does it for you.
How do you use the Emergency Equipment Checker?
- Choose your vehicle type and say whether the load is placarded hazmat.
- Choose your cargo type so the checker can apply the flame-device ban.
- Enter each fire extinguisher rating and answer the five condition checks.
- Enter how many triangles and fusees you carry and confirm the fusee spec.
- Describe the stop: road type, hill or curve, district, lighting and leaks.
- Read the verdict, the check table, the placement steps and the 10-minute clock.
Frequently asked questions
What fire extinguisher does a truck need?
A truck that is not hauling placarded hazmat needs one extinguisher rated 5 B:C or more, or two extinguishers each rated 4 B:C or more. A power unit hauling placarded hazmat needs one extinguisher rated 10 B:C or more. The extinguisher must carry its UL rating label, show a full charge on the gauge, be filled, be readily accessible and be securely mounted.
How many warning triangles must a truck carry?
Three bidirectional reflective triangles that meet FMVSS 125. The rule offers an alternative: at least 6 fusees, each burning 30 minutes and carrying the UL 912 mark. Either option satisfies 393.95(f) on its own. Red flags never substitute for the required devices.
Where do you place warning triangles on a truck?
On a two-way road, place one device 10 feet from the vehicle on the traffic side toward approaching traffic, one 100 feet behind the vehicle and one 100 feet ahead. On a divided or one-way road, place devices 10 feet from the rear, 100 feet back and 200 feet back, all toward approaching traffic. Near a hill or curve, move the far device out to between 100 and 500 feet.
Are spare fuses still required in a truck?
No. FMCSA removed the spare fuse requirement effective 20 April 2026 under 91 FR 7877. Section 393.95(b) now reads Reserved. Carrying spare fuses is still good practice, but no federal rule requires them. A citation for missing spare fuses written after the removal date can be challenged.
Can I use fusees on a hazmat load?
It depends on the cargo. Fusees are barred on vehicles transporting Division 1.1, 1.2 or 1.3 explosives and on cargo tank motor vehicles for Class 3 or Division 2.1, whether loaded or empty. They are also barred on vehicles using compressed gas as motor fuel. On other hazmat loads, including Class 3 in drums or totes, fusees stay legal. Use triangles on a banned load.
How long do you have to place warning devices?
As soon as possible. The outside limit is 10 minutes from the stop. The hazard flashers go on immediately at the stop and stay on until the devices are placed. The 10-minute clock starts when the vehicle stops, not when the driver starts placing devices.
Related tools
- Pre-Trip Inspection Checklist: Work through 46 pre-trip checks and flag out-of-service defects.
- Lighting and Reflector Checker: Check the lamps and reflectors your truck must show, plus the flasher that runs while you place warning devices.
- Railroad Crossing Stop Checker: Find out which trucks must stop at railroad crossings, 15 to 50 feet from the tracks.
- Hazmat Placard Checker: Check which placards your hazmat load needs. The placard result also sets the 10 B:C extinguisher rule.
- FMCSA Fine Calculator: Check the maximum FMCSA fine for any violation under 49 CFR Part 386.
- DataQs Challenge Helper: Challenge a DOT violation or crash through FMCSA DataQs, including a spare fuse citation written after 20 April 2026.
- Post-Accident Testing Decision Tool: Check whether DOT drug and alcohol testing is required after a crash, with the 2, 8 and 32-hour deadlines.
Sources
- 49 CFR 393.95, Emergency equipment on all power units (eCFR, issue of 16 Nov 2026, read 19 Nov 2026).
- 49 CFR 392.22, Emergency signals; stopped commercial motor vehicles (eCFR, issue of 16 Nov 2026, read 19 Nov 2026).
- 49 CFR 392.8, 392.24 and 392.25, emergency equipment inspection and use, flame-producing signals (eCFR, issue of 16 Nov 2026, read 19 Nov 2026).
- FMCSA, Parts and Accessories Necessary for Safe Operation; Spare Fuses, 91 FR 7877 (19 Feb 2026), effective 20 Apr 2026 (FR Doc 2026-03262).
- FMCSA, Parts and Accessories Necessary for Safe Operation; Liquid-Burning Flares, 91 FR 7867 (19 Feb 2026), effective 23 Mar 2026 (FR Doc 2026-03261).
- FMVSS No. 125, Warning devices, 49 CFR 571.125. UL 912, Highway Emergency Signals, 4th edition, 30 Jul 1979. Both are incorporated by reference in 49 CFR 393.95.