This tool checks the physical berth, not the hours of service clock. It tests the berth against every requirement in 49 CFR 393.76: size, shape, location, exit, equipment, ventilation, protection, plus occupant restraint. It does not work out split sleeper timing. For the timing, use the Sleeper Berth Split Calculator after the berth passes here.
Measure the berth with a tape measure first, then answer each question. Every answer updates the result as you change each field. All measurements are in inches.
About the berth
The installation date sets the size, shape, plus exit rules. The manufacture date sets whether the occupant restraint rule applies. A berth rebuilt or refitted after its first installation may count as newly installed: confirm the date with the upfitter documentation before relying on an older band.
Measurements, in inches
Measure length on the centerline of the longitudinal axis, width on the centerline of the transverse axis, plus height from the highest point of the top of the mattress. Enter 0 for the corner radius when the corners are square. With an adjustable mechanical suspension system, measure the height with the suspension adjusted to the height it settles to when occupied by a driver.
Shape and access
Location
Exit from the berth
Measure the clear opening, not the frame. For the two exit option, enter the smaller of the two exits, so the check tests the weaker one.
A communication device matters only when the berth sits outside the driver compartment with no direct entrance into it. With a direct exit, or with the berth inside the driver compartment, the rule does not apply.
Equipment
The thickness matters only for a foam or cellular rubber mattress, which must be at least 4 inches thick. Measure the thickness uncompressed, or read it from the mattress label.
Ventilation and protection
Occupant restraint
The restraint rule applies to motor vehicles manufactured on or after July 1, 1971. A factory-fitted sleeper restraint is built to this standard: check the manufacturer specification or the upfitter document when the rating is in doubt.
Verdict: Not compliant.
15 checks passed, 1 check failed, 1 not applicable.
This berth fails 1 requirement in 49 CFR 393.76. Until every failed check passes, the berth does not meet the federal standard. Time logged in it does not count as sleeper berth time under the definition in section 395.2. Fix the failed items below, then re-measure and run this check again.
The checks
| Requirement | Result | Detail |
|---|---|---|
| Length, section 393.76(a)(1) | Pass | Measured 75.0 in. Minimum for this date band: 75 in. At the minimum. |
| Width, section 393.76(a)(1) | Pass | Measured 24.0 in. Minimum for this date band: 24 in. At the minimum. |
| Height, section 393.76(a)(1) | Fail | Measured 23.5 in above the mattress. Minimum for this date band: 24 in. 0.5 in short. |
| Shape, section 393.76(a)(2) | Pass | Generally rectangular in shape. |
| Corner radii, section 393.76(a)(2) | Pass | Largest corner radius 6.0 in. Limit: 10.5 in. |
| Access, section 393.76(a)(3) | Pass | Ready entrance to the berth, plus ready exit from it, is not unduly hindered. |
| Location: trailer ban, section 393.76(b)(1) | Pass | Not installed in or on a semitrailer or a full trailer. |
| Location: cab and cargo space, section 393.76(b)(2) | Pass | In the cab or immediately adjacent to the cab and securely fixed with relation to the cab. |
| Exit, section 393.76(c)(1) | Pass | Measured 20.0 in high by 38.0 in wide. Required for a berth installed on or after January 1, 1963: at least 18 in high and 36 in wide. |
| Communication, section 393.76(d) | N/A | The berth has a direct entrance into the driver compartment, so no separate means of communication is required. |
| Bedding, section 393.76(e)(1) | Pass | Adequate bedclothing and blankets are provided. |
| Mattress, section 393.76(e)(2) | Pass | An innerspring mattress, one of the four options in section 393.76(e)(2). |
| Ventilation, section 393.76(f) | Pass | Louvers or another means of adequate ventilation are fitted. |
| Tight against dust and rain, section 393.76(f) | Pass | The berth is reasonably tight against dust and rain. |
| Protection from exhaust and fuel leaks, section 393.76(g) | Pass | Located so leaks in the exhaust system or fuel system do not let fuel, fuel system gases, or exhaust gases enter the berth. |
| Protection from exhaust heat, section 393.76(g) | Pass | Located so it will not be overheated or damaged by reason of proximity to the exhaust system. |
| Occupant restraint, section 393.76(h) | Pass | A restraint system is fitted to prevent ejection of the occupant during deceleration, designed to withstand 6,000 lb applied toward the front of the vehicle. |
The figures
| Figure | Value | Note |
|---|---|---|
| Installation date band | After September 30, 1975 | The size, shape, plus exit rules all turn on the date the berth was installed on the motor vehicle. |
| Required size | 75 in long, 24 in wide, 24 in high | Section 393.76(a)(1). Height is measured from the highest point of the top of the mattress. |
| Measured size | 75.0 in long, 24.0 in wide, 23.5 in high | Length on the centerline of the longitudinal axis. Width on the centerline of the transverse axis. |
| Length margin | At the minimum | Measured length minus the minimum for this date band. |
| Width margin | At the minimum | Measured width minus the minimum for this date band. |
| Height margin | 0.5 in short | Measured height minus the minimum for this date band. A thick replacement mattress can eat this margin. |
| Exit opening required | 18 in high, 36 in wide | Section 393.76(c)(1) for a berth installed on or after January 1, 1963. |
| Exit opening measured | 20.0 in high, 38.0 in wide | The doorway or opening into the driver seat or compartment. |
| Restraint force required | 6,000 lb forward | Section 393.76(h). The restraint system must withstand a minimum total force of 6,000 pounds applied toward the front of the vehicle, parallel to the longitudinal axis. |
What to do
- Raise the clearance above the mattress to 24 in. A thinner mattress, a lower bunk base, or a raised roof panel can recover the missing inches.
- Until every failed check passes, log rest in this berth as off duty, not sleeper berth.
- Re-measure after each fix and run this check again. Do not rely on the old measurements.
Before you log sleeper berth time
- Log rest in this berth as off duty until every failed check passes. Sleeper berth time in a non-compliant berth does not count as a qualifying rest period.
- Do not use the split sleeper provision with this berth until it passes. The berth period of a split must be spent in a berth that meets section 393.76.
- Keep this summary in the vehicle file with the measurement photos and the mattress and restraint specifications.
Notes
- Measure length on the centerline of the longitudinal axis, width on the centerline of the transverse axis, plus height from the highest point of the top of the mattress.
- If the berth uses an adjustable mechanical suspension system, the height clearance may be measured with the suspension adjusted to the height it settles to when occupied by a driver.
- The hours of service definition of sleeper berth points straight at this section. Section 395.2 defines a sleeper berth as a berth conforming to section 393.76.
- A thick replacement mattress can push a compliant berth under the height minimum. Re-check the height after any mattress change.
- This tool checks the physical berth only. It does not check hours of service timing, which is a Part 395 question.
This tool applies 49 CFR 393.76 to your inputs. Confirm the result against the regulation text plus the vehicle documentation before acting. A measurement taken wrong gives a wrong verdict, so re-measure any figure that sits close to a limit.
Your inputs stay in this browser. Nothing is sent to our servers. There is no account to create.
Disclaimer: This tool is a planning estimate based on the published text of 49 CFR 393.76, not legal advice — confirm the result plus any fix with FMCSA, a qualified upfitter, or your legal counsel before relying on it at inspection.
Quick answer: A truck sleeper berth must meet the physical standards in 49 CFR 393.76 to count as a sleeper berth at all. For a berth installed after September 30, 1975, the minimum size is 75 inches long, 24 inches wide, plus 24 inches of clearance above the mattress. The berth must be generally rectangular, located in the cab or immediately adjacent to it, with a direct exit into the driver seat or compartment at least 18 inches high plus 36 inches wide. It must carry adequate bedding plus a listed mattress, louvers or other ventilation, protection from exhaust plus fuel leaks, plus a restraint system rated to withstand 6,000 pounds of forward force on any vehicle built on or after July 1, 1971. This checker runs all 17 requirements in the section against your measurements plus answers, then names each fix.
What is a sleeper berth under federal law?
A sleeper berth is not any bed in a truck. Under federal law it is a berth that conforms to the requirements of 49 CFR 393.76. That is the whole definition: section 395.2 of the hours of service rules defines a sleeper berth as a berth conforming to the requirements of section 393.76. The physical rule in Part 393 therefore decides whether the time rule in Part 395 can ever apply. A space that fails the physical standard is not a sleeper berth in the eyes of the regulation, whatever the driver logs it as.
Two different rules share the name, which causes most of the confusion around sleeper berths. Section 393.76 is the equipment rule: it sets the physical standard for the berth itself, covering size, shape, location, exit, equipment, ventilation, protection, plus occupant restraint. Part 395 is the time rule: it sets how long a driver must rest in a qualifying berth, including the split sleeper provision in section 395.1(g), which lets a driver pair a berth period of at least 7 consecutive hours with a second rest period of at least 2 hours, the two totaling at least 10 hours. This checker covers the equipment rule only. For the timing, the Sleeper Berth Split Calculator works out whether a pair of rest periods qualifies as a split.
The equipment rule is one of the oldest stable rules in the Federal Motor Carrier Safety Regulations. It was issued in 1974 and last amended in 1988, when the Federal Register notice at 53 FR 49401 made its most recent change. The figures in it have not moved since. That stability cuts both ways: the rule is easy to learn once, but it also means a berth built to an old habit, such as a thin foam pad on a plywood shelf, has been non-compliant for decades, not merely out of fashion.
The rule binds motor carriers plus drivers together. A carrier must not operate a commercial motor vehicle with a berth that fails the standard. A driver must not log sleeper berth time in one. The check below runs all 17 requirements in the section, grouped by paragraph, against the measurements plus answers you enter. Each requirement carries its own pass or fail, so a single short measurement cannot hide behind an otherwise clean berth.
One more boundary matters before you start. This checker does not test hours of service timing, logbook status selection, or the 60/70 hour limits. Those are Part 395 questions. The HOS Recap Calculator works out the 60/70 hour balance plus the hours that come back each day. Use this checker first to confirm the berth itself qualifies, then use the hours tools to plan the rest.
What size must a sleeper berth be?
The minimum size turns on the date the berth was installed on the motor vehicle. Section 393.76(a)(1) sets three bands. The band decides all three dimensions at once. A berth installed after September 30, 1975 must be at least 75 inches long, 24 inches wide, plus 24 inches high. A berth installed between January 1, 1953 and September 30, 1975 must be at least 75 inches long, 21 inches wide, plus 21 inches high. A berth installed before January 1, 1953 must be at least 72 inches long, 18 inches wide, plus 18 inches high. Every truck on the road today with a factory sleeper falls in the newest band, so 75 by 24 by 24 is the figure that matters in practice.
| Date of installation | Length, minimum | Width, minimum | Height, minimum |
|---|---|---|---|
| Before January 1, 1953 | 72 in | 18 in | 18 in |
| January 1, 1953 to September 30, 1975 | 75 in | 21 in | 21 in |
| After September 30, 1975 | 75 in | 24 in | 24 in |
How the dimensions are measured matters as much as the numbers. Length is measured on the centerline of the longitudinal axis, which means down the middle of the berth from head to foot, not along a side wall that may run shorter. Width is measured on the centerline of the transverse axis, across the middle of the berth. Height is measured from the highest point of the top of the mattress, which means the mattress itself eats into the clearance. A berth shell with 30 inches of headroom above the bunk base holds only 22 inches of clearance under an 8 inch mattress. It fails the 24 inch rule by 2 inches.
One footnote softens the height rule for a specific design. Where the berth uses an adjustable mechanical suspension system, the required clearance may be measured with the suspension adjusted to the height it settles to when occupied by a driver. The rule recognizes that a suspended bunk sits higher empty than it does under a sleeper, so the measurement follows the occupied height. A fixed bunk gets no such allowance: measure it as it stands.
The date bands are a form of grandfathering. Older berths are held to the standard of their time, not to the modern one, so a 1950s berth that meets the 72 by 18 by 18 figures is compliant even though it would fail as a new installation. The grandfathering follows the installation date, not the vehicle age: a berth fitted to an old truck last year is a new installation under the newest band. If a berth was rebuilt or refitted, confirm which installation date applies from the upfitter documentation before relying on an older band.
The height figure is the one that fails most often in practice. Length plus width are set by the cab shell, which the manufacturer built to the rule, while height depends on the mattress the owner chose. A thick premium mattress, a mattress topper, or a second pad stacked on the first can push a compliant berth under the line without anyone noticing. Re-check the height after any mattress change. The checker shows the margin on each dimension, so a berth sitting exactly at the minimum reads as passing, while a berth half an inch short reads as failing with the shortfall named.
Worked example: a berth measuring 75 inches long, 24 inches wide, plus 23.5 inches above the mattress fails on height alone. The shortfall is half an inch. The fix is a mattress half an inch thinner, a bunk base lowered by half an inch, or a roof panel raised by half an inch. Any one of the three restores compliance. The checker confirms it the moment the new height is entered.
What shape must a sleeper berth be?
A sleeper berth installed on or after January 1, 1953 must be of generally rectangular shape. The rule allows one departure: the horizontal corners plus the roof corners may be rounded to radii not exceeding 10.5 inches. A berth installed before January 1, 1953 carries no shape rule at all, which is why the checker marks shape as not applicable for the oldest band.
Generally rectangular is a practical standard, not a geometry test. A sleeper with a curved roof line, a sloped front wall following the cab back, or rounded corners inside the 10.5 inch radius still reads as generally rectangular. A berth shaped as a triangle, a wedge, or a tube does not. The question the rule asks is whether the space reads as a rectangular sleeping compartment with ordinary corners, not whether every angle measures 90 degrees.
The corner radius limit deserves its own measurement. A radius of 10.5 inches is a generous curve: a quarter circle with a radius just under 11 inches. Most factory sleepers use far smaller radii, in the range of 4 to 8 inches, so the limit rarely bites on a production truck. It bites on custom builds, where a builder rounds a corner hard to gain floor space, or on converted boxes where a curved wall eats the corner entirely. Measure the largest rounded corner, not the average one, because the rule caps each corner.
Shape has a companion rule that owners overlook. Section 393.76(a)(3) requires the berth to be constructed so that ready entrance to, plus ready exit from, the berth is not unduly hindered. A berth can pass every dimension plus still fail this rule when the path in is blocked: a cooler parked in the opening, a storage bin bolted across the entry, a curtain rail that traps the occupant, or a bunk stacked so high with gear that the driver must crawl over it. The test is the occupant experience, not the tape measure. If getting in or out takes effort beyond normal movement, the access rule is in play.
When the shape check fails, the radius check becomes not applicable in this checker, because the radius limit governs the corners of a generally rectangular berth. Fix the shape first, then measure the corners of the rebuilt berth. A rebuild that restores a rectangular outline usually brings the corners inside the limit as a side effect.
Where can a sleeper berth be installed?
Location is the requirement that most often surprises a buyer. Section 393.76(b)(2) requires a berth installed on or after January 1, 1953 to be located in the cab or immediately adjacent to the cab, plus securely fixed with relation to the cab. A sleeper built into the tractor cab, or in a sleeper box bolted directly behind it, satisfies the rule. A sleeping space anywhere else in the combination does not.
The trailer ban is absolute. Section 393.76(b)(1) states that a sleeper berth must not be installed in or on a semitrailer or a full trailer other than a house trailer. A bed in a dry van, a reefer, or a flatbed trailer is not a sleeper berth under the regulation, however comfortable it may be. Time logged in it does not count as sleeper berth time. The single exception is a house trailer, which the regulation treats as living quarters rather than freight equipment.
The house trailer exception has a limit that the checker applies. The exception in paragraph (b)(1) excuses a house trailer berth from the trailer ban, but it does not excuse the cab location rule in paragraph (b)(2). A berth in a house trailer installed on or after January 1, 1953 still has to sit in the cab or immediately adjacent to it, which a towed house trailer cannot satisfy. In practice the exception covers older house trailer berths plus the pre-1953 band, where the cab rule does not apply. A buyer looking at a house trailer berth on a modern truck should treat it as non-compliant unless the installation predates 1953.
Cargo space berths follow their own sentence in paragraph (b)(2). A sleeper berth located within the cargo space of a motor vehicle must be securely compartmentalized from the remainder of the cargo space. The rule targets straight trucks plus expediters, where the sleeping area shares the box with freight. A curtain is not compartmentalization. The berth needs a solid partition that separates it from the cargo area, so freight cannot shift into the sleeping space and so the occupant is not sleeping among the load. For a berth installed on or after January 1, 1953, compartmentalization alone is not enough: the berth must also sit in the cab or immediately adjacent to it, which a cargo space berth behind the cab usually fails.
Securely fixed is the last location test. It rules out the improvised berth. A mattress laid on the cab floor, a bunk resting loose on brackets, or a sleeper pod held in place by gravity alone is not securely fixed with relation to the cab. The berth must be mounted, bolted, or otherwise fastened so it stays put under braking plus cornering. The restraint rule in paragraph (h) protects the occupant during deceleration; the securely fixed rule protects the berth itself. Both point at the same event: a hard stop must not turn the sleeping area into a projectile.
Location answers are the hardest to change after the fact, which is why the checker tests them early in the list. A berth in the wrong place cannot be fixed with a new mattress or a vent. It has to move, which usually means a different truck or a different sleeper installation. Check the location before buying a used truck with an unusual sleeper, plus before paying an upfitter for a custom build.
What exit must a sleeper berth have?
Every sleeper berth needs a way out that works in an emergency. Section 393.76(c)(1) requires a direct and ready means of exit from the berth into the driver seat or compartment. The exit must lead to the driving position, not merely to the outside air. The reason is practical: a driver resting in the berth must be able to reach the controls, or to leave through the cab, without climbing out of the vehicle first.
The size of that exit turns on the installation date, with the dividing line at January 1, 1963. A berth installed on or after that date needs a doorway or opening at least 18 inches high plus 36 inches wide. A berth installed before that date needs an exit with sufficient area to contain an ellipse having a major axis of 24 inches plus a minor axis of 16 inches. The two tests measure the same idea in different language: the opening must be large enough for an adult to pass through quickly.
| Date of installation | Exit requirement |
|---|---|
| Before January 1, 1953 | Ellipse 24 in by 16 in, or two exits each 18 in high by 21 in wide at opposite ends of the vehicle |
| January 1, 1953 to December 31, 1962 | Opening large enough for an ellipse 24 in by 16 in |
| On or after January 1, 1963 | Doorway or opening at least 18 in high by 36 in wide |
The ellipse test needs a working reading, because the regulation does not say how to fit the ellipse into the opening. This checker reads it the way inspectors apply it: the opening must take 24 inches in one direction plus 16 inches in the other. An opening 16 inches high by 24 inches wide passes. So does an opening 24 inches high by 16 inches wide. An opening 15 inches high by 24 inches wide fails, because no orientation fits the 16 inch minor axis. The reading is conservative. It matches the plain intent of the rule.
Berths installed before January 1, 1953 get a second option that no later berth can use. Section 393.76(c)(2) lets a pre-1953 berth have at least two exits instead of a direct exit into the driver compartment, provided each exit is at least 18 inches high plus 21 inches wide, the exits sit at opposite ends of the vehicle, plus each is usable by the occupant without the assistance of any other person. The alternative exists because very old vehicles were built before the cab exit standard. A berth from 1953 or later cannot use it: the checker fails any post-1952 berth that offers two exits instead of a direct one.
The exit rule has a companion in paragraph (d), the communication rule. A sleeper berth which is not located within the driver compartment plus has no direct entrance into the driver compartment must be equipped with a means of communication between the occupant plus the driver. The regulation lists a telephone, a speaker tube, a buzzer, a pull cord, or any other mechanical or electrical device. The rule covers the separate sleeper box, where the resting driver cannot see or hear the driver at the wheel. A standard integrated sleeper never triggers it, because the direct exit into the cab is itself the communication path. The checker marks communication as not applicable whenever the berth has a direct exit or sits within the driver compartment.
Measure the exit as a clear opening. A doorway 36 inches wide on the frame but 33 inches wide between the trim fails the width test, because the occupant passes through the clear space, not the frame. Check the opening with the curtain or door in its normal open position, not removed, since the regulation tests the berth as used.
What equipment must a sleeper berth have?
A sleeper berth must be properly equipped for sleeping. Section 393.76(e) breaks that duty into two parts: adequate bedclothing plus blankets under paragraph (e)(1), plus a mattress of a listed type under paragraph (e)(2). Both parts must be present. Bedding without a mattress fails. A mattress without bedding fails.
The mattress rule gives four options. Any one of them satisfies it. The berth may carry springs plus a mattress, an innerspring mattress, a cellular rubber or flexible foam mattress at least four inches thick, or a mattress filled with a fluid and of sufficient thickness when filled to prevent bottoming out when occupied while the vehicle is in motion. The list is closed: a sleeping pad, an air mattress that is not a fluid mattress, or a bare bunk board is not among the options.
| Mattress option | What the rule requires |
|---|---|
| Springs and a mattress | A spring base plus a mattress on top of it |
| Innerspring mattress | A mattress with an inner spring unit |
| Cellular rubber or flexible foam | At least 4 inches thick |
| Fluid-filled mattress | Thick enough when filled to prevent bottoming out while occupied in motion |
The foam option carries the only thickness number in the equipment rule: four inches. Measure the foam uncompressed, or read the thickness from the mattress label, because a foam pad that measures 4 inches on the shelf may measure less under load. A 3 inch foam pad, however dense, fails the rule outright. The checker asks for the foam thickness only when the foam option is selected. It tests the figure against the 4 inch floor.
The fluid mattress option carries a performance test instead of a number. The mattress must be of sufficient thickness when filled to prevent bottoming out when occupied while the vehicle is in motion. Bottoming out means the occupant sinks through the fluid layer until the body rests on the bunk base. A waterbed filled to the marked level passes. The same mattress underfilled, or a fluid pad too thin for the occupant weight, fails. The test is the occupied mattress in motion, not the empty mattress at rest.
Springs plus a mattress is the oldest option on the list. It still appears in older sleepers plus some custom builds. The rule does not set a thickness for it, because the spring unit plus mattress together define the sleeping surface. An innerspring mattress, the modern default in factory sleepers, needs no separate spring base. Either option passes the checker without a thickness figure.
Bedding is a judgment call. The checker asks it as one. Adequate bedclothing plus blankets means the berth carries the sheets, blankets, plus covering a sleeper needs for the climate the truck runs in. A bare mattress with no covering fails. A berth with sheets plus a blanket passes. The inspector test is whether a driver could sleep in the berth as found, not whether the bedding matches a hotel standard.
What ventilation and protection does a sleeper berth need?
Section 393.76(f) sets two duties in one paragraph: the berth must have louvers or other means of providing adequate ventilation, plus it must be reasonably tight against dust plus rain. The two duties pull in opposite directions, which is why the regulation states them together: the berth must breathe without leaking.
Louvers are the named example, but the rule accepts any means of adequate ventilation. A roof vent, a window that opens, a powered vent fan, or a ducted fresh air supply all satisfy it, provided the airflow is adequate for a person sleeping in an enclosed space. A sealed box with no vent fails, however well insulated it may be. The test is whether fresh air reaches the occupant, not whether a specific device is fitted.
Reasonably tight against dust plus rain is a condition test, not a design test. Seals age, gaskets shrink, door fits loosen, plus roof seams open up. A berth that passed when new can fail ten years later because rain now enters at a seam or dust blows in around a worn seal. Check the berth in wet weather or after a dusty run: water stains on the bunk, dust lines around the door, or a damp mattress all point at a failed seal. The checker asks the question as a yes or no, because the owner knows the berth condition better than any measurement can show.
Section 393.76(g) sets the protection duties. They are the most safety critical part of the section. The berth must be located so that leaks in the vehicle exhaust system or fuel system do not permit fuel, fuel system gases, or exhaust gases to enter the sleeper berth. Exhaust gas in a sleeping compartment is a carbon monoxide risk. The rule is written to keep the sleeper separated from every leak path: exhaust joints, fuel lines, plus tank vents. A berth mounted above an exhaust joint, or beside a fuel line with no barrier, fails the location test even when nothing is leaking today, because the rule tests the location against a future leak.
The same paragraph covers heat. The berth must be located so that it will not be overheated or damaged by reason of its proximity to the vehicle exhaust system. Exhaust pipes run hot enough to scorch a bunk base, melt a mattress, or raise the sleeping space to an unsafe temperature. Heat shields, air gaps, plus routing distance are the usual answers. A berth pressed against an unshielded exhaust stack fails. A berth with a shielded pipe running beneath the floor, separated by an air gap plus insulation, passes.
Both protection checks are location checks, like the cab rule, which means the fix is usually relocation or shielding rather than a part swap. When either check fails, look at the exhaust routing first: a rerouted pipe or an added heat shield is often cheaper than moving the berth. Keep the repair document with the vehicle file, since an inspector who sees a shield wants to know it was fitted deliberately.
What restraint does a sleeper berth need?
Section 393.76(h) requires an occupant restraint on every motor vehicle manufactured on or after July 1, 1971 that is equipped with a sleeper berth. The restraint must prevent ejection of the occupant during deceleration of the vehicle. It must be designed, installed, plus maintained to withstand a minimum total force of 6,000 pounds applied toward the front of the vehicle plus parallel to the longitudinal axis of the vehicle.
The date line is a manufacture date, not an installation date. A truck built on June 30, 1971 with a sleeper needs no restraint under this paragraph. A truck built on July 1, 1971 needs one. Every truck on the road today was built long after the line, so the restraint rule applies to every sleeper a buyer will meet. The checker marks it not applicable only when the vehicle predates July 1971.
The 6,000 pound figure is a total force rating, not a per strap number. It measures the load the whole restraint system must withstand when the vehicle decelerates hard and the occupant mass drives forward. The direction matters: the force applies toward the front of the vehicle, parallel to the longitudinal axis, which is the direction a sleeper moves in a frontal stop. A restraint rated for a sideways load, or for a static weight, does not answer the rule.
What counts as a restraint is left to the manufacturer plus the upfitter. Factory sleepers carry a restraint net, a belt, or a bar system fitted to the bunk, built to the 6,000 pound standard as part of the cab certification. Aftermarket sleepers need a restraint fitted to the same standard, with documentation from the upfitter. The checker asks whether a rated restraint is fitted, because the owner or the upfitter holds the rating document. A net with no rating, a belt bolted to thin paneling, or a restraint whose mounts have rusted through fails the rule even when it looks intact.
Maintenance is part of the rule text: designed, installed, plus maintained to withstand the force. A restraint that met the standard when fitted but has since frayed, stretched, or lost a mounting bolt no longer meets it. Check the webbing for wear, the mounts for tightness, plus the anchor points for corrosion at every service. The restraint is the only item in the section that protects the occupant during a crash rather than during rest, which is why the checker treats a missing or unrated restraint as a hard fail.
Vehicles built before July 1, 1971 are exempt, but an owner restoring one should fit a restraint anyway. The exemption is a grandfather clause, not a safety finding. A restraint built to the modern standard costs little against the risk it covers. It removes the one question a buyer always asks about an old sleeper.
What happens if a sleeper berth does not comply?
The first consequence is an hours of service problem, not a fine. Section 395.2 defines a sleeper berth as a berth conforming to section 393.76, so time logged in a non-compliant berth does not count as sleeper berth time. A 10 hour break logged in such a berth is not a qualifying rest period. A split built on it fails: the berth period of the split must be spent in a berth that meets the physical standard. The Sleeper Berth Split Calculator assumes a qualifying berth before it tests the timing. A driver who discovers the defect mid-trip should log the rest as off duty, not sleeper berth, until the berth passes.
The second consequence is an inspection violation. A berth defect is a Part 393 violation, cited on the roadside inspection report under section 393.76. It counts toward the carrier Vehicle Maintenance BASIC in the Safety Measurement System. A single berth citation will not sink a carrier record, but it joins every other vehicle violation in the same BASIC. A pattern of vehicle findings is what draws FMCSA attention. The penalty for a violation is set in Appendix B to Part 386, which FMCSA adjusts for inflation: check the current appendix before quoting a figure. Use the FMCSA Fine Calculator to work out the current amount for a given violation.
The fix path is straightforward. The checker lays it out. Each failed check carries its own fix in the action list: lengthen, widen, or raise the berth; rebuild the shape; clear the access path; move the berth; enlarge the exit; fit a communication device; add bedding or a listed mattress; fit louvers; seal the berth; shield it from exhaust; fit a rated restraint. Fix the failed items, re-measure, plus run the check again. Do not rely on the old measurements after a fix, because a rebuild changes more than the item it targets.
Buying a used truck is the moment this check pays for itself. A sleeper that looks clean can hide a shortfall of half an inch in height, a foam pad under 4 inches, or a restraint with no rating document. Run the checker on the truck before purchase, with a tape measure in hand. Ask the seller for the upfitter documentation on any custom sleeper. A seller who cannot produce the restraint rating or the mattress specification is selling a berth that may not pass.
Short-haul drivers rarely need a berth at all, which is worth remembering before investing in a fix. A driver who stays within the short-haul radius plus returns to the home terminal each day has no use for sleeper berth time. The 16-Hour Short-Haul Exception Checker covers the short-haul rules. The Adverse Driving Conditions Checker covers the extra time allowed when weather or traffic turns against the driver. A berth fix is money well spent for a long-haul operation. It is money wasted on a truck that never sleeps away from home.
How do you measure a sleeper berth?
Start with a tape measure, a straight edge, plus a helper. The helper holds the tape at one end while you read the other, which matters for the length measurement down the centerline. Measure with the mattress in place, because the height rule measures from the top of the mattress, plus with the bedding as normally used, because the bedding is part of the berth the regulation tests.
Length first: run the tape down the centerline of the longitudinal axis, from the head end to the foot end, along the middle of the sleeping surface. Do not measure along a side wall, which may run shorter around a curve or a cabinet. Width next: run the tape across the centerline of the transverse axis, from one side to the other, at the middle of the berth length. Height last: measure straight up from the highest point of the top of the mattress to the ceiling above it, at the point where the clearance is smallest. The smallest clearance governs, because the occupant sleeps under the lowest part of the roof.
Measure the exit as a clear opening. Open the doorway or curtain to its normal open position, then measure the height plus the width of the space an occupant passes through. Ignore the frame: the regulation tests the opening, not the surround. For the two exit alternative on a pre-1953 berth, measure both exits, then enter the smaller one, so the checker tests the weaker exit.
Measure the corner radius with a radius gauge if one is available, or with a tape plus a straight edge. Lay the straight edge along one wall into the corner, mark where the curve leaves the straight line, then measure from that point to the corner apex along each wall. The longer of the two runs approximates the radius. When the corner is square, enter 0. When the radius is close to the 10.5 inch limit, measure again with a gauge, because a half inch either way decides the check.
Measure the mattress thickness uncompressed, or read it from the mattress label. A foam pad compresses under a hand, so pressing the tape into it gives a false low reading. Lay the tape beside the mattress edge instead. For a fluid mattress, check the fill level against the manufacturer mark, then test for bottoming out by lying on it: if the body reaches the bunk base, the mattress fails regardless of its filled thickness.
Record everything. Photograph each measurement with the tape in the frame, note the figures in writing, plus file the record with the vehicle documents. The record answers the next inspector, the next buyer, plus the next upfitter. It proves the berth passed on the date measured. Add the berth to the daily walkaround: the DVIR Checker covers the daily vehicle inspection report. The Annual Inspection Due-Date Tracker works out when the next periodic inspection falls due, so the truck inspection stays current alongside the berth check.
How do you use the Sleeper Berth Compliance Checker?
Work through the fields in order. The tool updates with every change, so you can fix an answer and watch the verdict change.
- Pick the installation date band for the berth.
- Measure the length, width, plus height with a tape measure.
- Measure the exit opening and the largest corner radius.
- Answer the location, equipment, ventilation, plus protection questions.
- Read the verdict and the per-requirement table.
- Fix each failed item, re-measure, plus run the check again.
Use measurements from the truck, not from a brochure. A manufacturer specification sheet gives the design figures, which may differ from the berth as built plus as worn. A mattress changed since the truck left the factory changes the height figure. A bunk base repaired after a collision changes the length. The checker is only as good as the tape measure behind it.
Read the figures table before the action list. It shows the required size for the date band, the measured size, plus the margin on each dimension, so you can see which dimension is closest to failing even when the berth passes. A berth that passes with a height margin of zero will fail the next time the mattress is changed. The figures table is where that risk shows.
Questions drivers ask
What size must a truck sleeper berth be?
For a berth installed after September 30, 1975, the minimum is 75 inches long, 24 inches wide, plus 24 inches of clearance above the mattress, under 49 CFR 393.76(a)(1). Older berths follow smaller minimums: 75 by 21 by 21 inches for berths installed between January 1, 1953 and September 30, 1975, plus 72 by 18 by 18 inches for berths installed before January 1, 1953. Height is measured from the highest point of the top of the mattress.
Does a sleeper berth have to be in the cab?
Yes, for berths installed on or after January 1, 1953. Section 393.76(b)(2) requires the berth to be located in the cab or immediately adjacent to the cab, plus securely fixed with relation to the cab. A berth in or on a semitrailer or full trailer is banned outright, except in a house trailer. A berth within the cargo space must be securely compartmentalized from the rest of the cargo space.
What exit does a sleeper berth need?
A direct and ready exit into the driver seat or compartment. For a berth installed on or after January 1, 1963, the doorway or opening must be at least 18 inches high plus 36 inches wide. For a berth installed before January 1, 1963, the exit must hold an ellipse with a major axis of 24 inches plus a minor axis of 16 inches. Berths installed before January 1, 1953 may instead have two exits, each at least 18 inches high plus 21 inches wide, at opposite ends of the vehicle.
What mattress does a sleeper berth need?
One of four options under section 393.76(e)(2): springs plus a mattress, an innerspring mattress, a cellular rubber or flexible foam mattress at least 4 inches thick, or a fluid-filled mattress thick enough when filled to prevent bottoming out when occupied while the vehicle is in motion. Adequate bedclothing plus blankets are required in addition to the mattress.
Does a sleeper berth need a seat belt or restraint?
Yes, on a motor vehicle manufactured on or after July 1, 1971. Section 393.76(h) requires a means of preventing ejection of the occupant during deceleration, designed, installed, plus maintained to withstand a minimum total force of 6,000 pounds applied toward the front of the vehicle. Factory sleepers carry a restraint net, belt, or bar system built to that standard.
What happens if a sleeper berth does not meet 49 CFR 393.76?
Time logged in the berth does not count as sleeper berth time, because section 395.2 defines a sleeper berth as a berth conforming to section 393.76. A split built on such a berth fails. The defect is also a Part 393 violation at roadside inspection, cited under section 393.76, counting toward the carrier Vehicle Maintenance BASIC. Fix the failed items, re-measure, plus run this check again before logging sleeper berth time in it.
Related tools
- Sleeper Berth Split Calculator: work out whether a pair of rest periods qualifies as a split under section 395.1(g).
- HOS Recap Calculator: work out the 60/70 hour balance plus the hours that come back each day.
- DVIR Checker: check the daily vehicle inspection report plus the defects it must record.
- FMCSA Fine Calculator: work out the current inflation-adjusted penalty for a given FMCSA violation.
Sources
- 49 CFR 393.76, Sleeper berths (eCFR, read verbatim Nov 19, 2026; last amended 53 FR 49401, Dec. 7, 1988)
- 49 CFR 395.2, Definitions (eCFR, read verbatim Nov 19, 2026; sleeper berth means a berth conforming to section 393.76)
- 49 CFR 395.1, Scope of rules in this part (eCFR; sleeper berth provision at section 395.1(g))
- 49 CFR 395.3, Maximum driving time for property-carrying vehicles (eCFR; 10 hour rest rule)