Skip to main content

Trucking Mind

One pair at a time. This checker reads the segregation table in 49 CFR 177.848 for two hazard classes or divisions, plus the subsidiary hazard rule, the special bans in paragraph (c) and the ammonium nitrate exception in Note A. An X verdict means the pair must not ride together. Do not try to fix an X pair with extra separation.

Pick two hazard classes or divisions from the shipping papers. Add a subsidiary hazard when a package bears one. Every answer updates as you change each field.

The two materials

Subsidiary hazards (optional)

When a package bears a subsidiary hazard label, segregation for the subsidiary hazard applies when it is more restrictive than the primary hazard. See 177.848(e)(6).

Extra facts

Load together only if separated

O: separated so leakage cannot mix the two materials

The segregation table in 177.848(d) marks this pair with an O. The two materials may ride together only if they are separated in a manner that, in the event of leakage from packages under conditions normally incident to transportation, commingling of the hazardous materials would not occur.

The checks

CheckResultDetail
Segregation table cellO: separated49 CFR 177.848(d), Class 3 with Division 5.1.

What to do

  • Separate the two materials so that a leak from one cannot reach the other under normal transport conditions.
  • Use a physical barrier, a separate compartment or enough distance between the loads. Check the separation before departure.
  • Check the shipping papers: a subsidiary hazard label can change an O pair into an X pair.

Notes

  • Separation is judged by the leak test, not by distance alone: if a package leaked in normal transport, would the contents mix? If yes, the separation fails.

This checker applies 49 CFR 177.848 to your answers. Confirm the result against the current regulation and your company policy before you rely on it.

Your inputs stay in this browser. Nothing is sent to our servers. There is no account to create.

Disclaimer: This tool is provided for general information only. It is not legal advice — check the current regulation and your company policy before you rely on a result.

Quick answer: Two hazmat classes may share a vehicle only when the segregation table in 49 CFR 177.848 allows it. The table gives four answers. X means the pair may not be loaded together. O means the pair may ride together only if separated so that a leak cannot mix the two materials. A blank cell means no restriction applies. A star sends Class 1 pairs to the compatibility table in paragraph (f). This checker reads the table for any two classes. It applies the subsidiary hazard rule in (e)(6), the special bans in paragraph (c) and the ammonium nitrate exception in Note A. It gives a plain verdict with the exact cell and citation.

Last reviewed: · Focus keyword: hazmat segregation table

What is the hazmat segregation table in 49 CFR 177.848?

The segregation table is the federal chart that decides which hazardous materials may share a transport vehicle or a storage facility. It sits in 49 CFR 177.848, in the highway carriage rules of the Hazardous Materials Regulations. A driver, loader or dispatcher reads two classes off the shipping papers, finds the cell where the row meets the column. That cell gives one of four answers: X, O, blank or a star. The checker on this page does that lookup for any pair, then applies the extra rules that sit around the table.

The section applies to materials that meet one or more hazard classes and are in packages that must be labeled or placarded under Part 172, in a compartment of a multi-compartmented cargo tank under section 173.33, or in a portable tank loaded in a transport vehicle or freight container. It covers storage, loading and transport together, so the same cell governs the warehouse shelf and the trailer. When a transport vehicle itself travels by vessel, other than a ferry vessel, the vessel stowage rule in section 176.83(b) governs instead.

The table has 18 rows and 18 columns. Divisions 1.1 and 1.2 share one row and one column because the table treats them alike. Division 2.3 splits into Hazard Zone A and Hazard Zone B because the two zones segregate differently: Zone A earns an X where Zone B earns an O against the same eight classes. Division 6.1 appears only as PG I Zone A liquids. Class 8 appears only as liquids. Every other class appears whole. The checker follows the table exactly, with Division 1.1 and Division 1.2 offered as separate picks that share one axis.

The stakes are practical. A leak from one package onto an incompatible load can start a fire, release a toxic gas or set off an explosion. The table is the legal minimum for keeping that from happening. Carrier policy or shipper instructions can be stricter than the table. A stricter company rule still binds the driver. The table never overrides a stricter rule that applies to the load.

Segregation starts from the hazard class on the shipping paper. The class also drives placarding. When the load needs placards, the Hazmat Placard Checker gives the required placards for the same classes.

What do X, O, blank and the star mean in the segregation table?

Paragraph (e) of section 177.848 gives the instructions for reading the table. Four marks cover every cell. The letter X means the materials may not be loaded, transported or stored together in the same transport vehicle or storage facility during the course of transportation. The table holds 104 X cells, which is 52 unique pairs once the mirror cells are counted once.

The letter O means the materials may ride together only if separated in a manner that, in the event of leakage from packages under conditions normally incident to transportation, commingling of the hazardous materials would not occur. The table holds 44 O cells, which is 22 unique pairs. Separation is judged by the leak test: if a package leaked in normal transport, would the contents mix?

A blank space means no restriction applies. Paragraph (e)(1) says the same about a hazard class that does not appear in the table at all. The table holds 151 blank cells. A blank cell answers the segregation question only. Placarding, shipping papers, loading rules and carrier policy still apply to the load.

The star means segregation among different Class 1 materials is governed by the compatibility table in paragraph (f). The star fills the whole 5 by 5 Class 1 block: 25 cells. Two explosives need their compatibility groups before the answer is known. The checker asks for both groups whenever the table shows a star.

The full table follows, exactly as printed in 177.848(d). Rows and columns use the same 18 headings. Read across from the first class and down from the second class. The table is symmetric: the cell for Class 3 with Division 5.1 matches the cell for Division 5.1 with Class 3.

Class1.1/1.21.31.41.51.62.12.22.3 A2.3 B34.14.24.35.15.26.1 A78
1.1/1.2*****XXXXXXXXXXXXX
1.3*****XXXXXXXXXX
1.4*****OOOOOOO
1.5*****XXXXXXXXXXXXX
1.6*****
2.1XXOXXOOO
2.2XX
2.3 AXXOXXXXXXXXX
2.3 BXXOXOOOOOOOO
3XXOXXOOX
4.1XXXOXO
4.2XXOXXOXX
4.3XXXXOXO
5.1XXXXOOXO
5.2XXXXOXO
6.1 AXXOXOXXXXXXX
7XXO
8XXOXXOOXOOOX

Which hazmat classes can never ride together?

Fifty-two unique pairs carry an X. Thirty-six of them involve a Class 1 row or column. Explosives dominate the forbidden list because almost nothing may ride with them: Divisions 1.1 and 1.2 and Division 1.5 carry an X against every one of the 13 non-Class 1 columns. Division 1.3 carries an X against 10 of the 13.

Division 1.4 is the mildest explosive division. It carries no X at all outside the Class 1 block. Its seven marks outside the block are all O cells, against Division 2.1, Division 2.3 Zone A, Division 2.3 Zone B, Class 3, Division 4.2, Division 6.1 PG I Zone A and Class 8 liquids. Division 1.6 is milder still: its whole row is blank. Extremely insensitive articles carry no segregation restriction in the table.

Sixteen forbidden pairs involve no explosive at all. Poisonous gas Zone A and poisonous liquid PG I Zone A account for most of them. Zone A gas may not ride with flammable gas, flammable liquid, flammable solid, spontaneously combustible material, dangerous when wet material, oxidizer, organic peroxide or corrosive liquid. The PG I Zone A liquid may not ride with flammable liquid, flammable solid, spontaneously combustible material, dangerous when wet material, oxidizer, organic peroxide or corrosive liquid. The two remaining pairs are Division 4.2 with Class 8 liquids and Division 2.1 with Division 2.3 Zone A.

First classSecond classTable cell
Division 2.1Division 2.3 Zone AX: may not load together
Division 2.3 Zone AClass 3X: may not load together
Division 2.3 Zone ADivision 4.1X: may not load together
Division 2.3 Zone ADivision 4.2X: may not load together
Division 2.3 Zone ADivision 4.3X: may not load together
Division 2.3 Zone ADivision 5.1X: may not load together
Division 2.3 Zone ADivision 5.2X: may not load together
Division 2.3 Zone AClass 8 liquidsX: may not load together
Class 3Division 6.1 PG I Zone AX: may not load together
Division 4.1Division 6.1 PG I Zone AX: may not load together
Division 4.2Division 6.1 PG I Zone AX: may not load together
Division 4.2Class 8 liquidsX: may not load together
Division 4.3Division 6.1 PG I Zone AX: may not load together
Division 5.1Division 6.1 PG I Zone AX: may not load together
Division 5.2Division 6.1 PG I Zone AX: may not load together
Division 6.1 PG I Zone AClass 8 liquidsX: may not load together

The pattern is worth learning. The most toxic inhalation hazards, Zone A gas and PG I Zone A liquid, are the classes most often banned from sharing a load with ordinary freight classes. A Zone A load on a mixed trailer deserves a check before anything else is loaded beside it.

What does separated mean for an O pair?

An O pair may ride together, but only with separation that passes the leak test in paragraph (e)(3). The rule asks a concrete question: if a package leaked under conditions normally incident to transportation, would the hazardous materials commingle? When the answer is yes, the separation fails, whatever the distance between the loads. A physical barrier, a separate compartment or enough distance can each pass the test when the leak cannot cross it.

One extra rule binds every O pair that includes Class 8 liquids with a Class 4 or Class 5 material. Paragraph (e)(3) says Class 8 liquids may not be loaded above or adjacent to Class 4 or Class 5 materials, notwithstanding the methods of separation employed. The pairs this touches are Class 8 liquids with Division 4.1, Division 4.3, Division 5.1 and Division 5.2. Division 4.2 with Class 8 liquids is an X pair, so the above-or-adjacent rule never arises for it.

The truckload exception is narrow. Shippers may load truckload shipments of such materials together when it is known that the mixture of contents would not cause a fire or a dangerous evolution of heat or gas. Known is the operative word: a guess about compatibility does not meet it. The checker flags the above-or-adjacent rule on every O result it touches.

Separation planning starts before loading. When the load includes a material you do not know well, the ERG Guide-Number Lookup gives the emergency response guide for its UN number, including the hazards that make separation matter.

How do explosives use the compatibility table?

Two explosives never get a plain X or O from the segregation table. Every Class 1 pair shows a star. Paragraph (e)(4) sends the question to the compatibility table in paragraph (f). That table has 13 compatibility groups, lettered A through S, with 169 cells. Most of them are X: 116 cells carry a plain X and 2 more carry X(4). Only 12 cells are blank.

The group letter comes from the classification code on the shipping paper, for example 1.1D or 1.4S. The division alone does not fix the group. Division 1.1 alone spans nine groups. Division 1.2 spans ten. Division 1.5 has only group D. Division 1.6 has only group N. Group S exists only as 1.4S. The checker validates each group against its division and rejects a combination that does not exist.

GroupABCDEFGHJKLNS
AXXXXXXXXXXXX
BXXX(4)XXXXXXXX4/5
CXX22X6XXXX34/5
DXX(4)22X6XXXX34/5
EXX22X6XXXX34/5
FXXXXXXXXXXX4/5
GXX666XXXXXX4/5
HXXXXXXXXXXX4/5
JXXXXXXXXXXX4/5
KXXXXXXXXXXX4/5
LXXXXXXXXXX1XX
NXX333XXXXXX4/5
SX4/54/54/54/54/54/54/54/54/5X4/5

The numbered notes carry the fine print. Note 1 says an explosive from group L shall only be carried with an identical explosive. Note 2 assigns any combination of groups C, D or E to group E. Note 3 assigns a combination of groups C, D or E with group N to group D. Note 4 points to the detonator rule in section 177.835(g). Note 5 says Division 1.4S fireworks may not be loaded with Division 1.1 or 1.2 materials. Note 6 lets group G articles, other than fireworks and those requiring special handling, ride with group C, D and E articles, provided no loose explosive substance rides in the same vehicle.

Two more paragraphs shape mixed explosive loads. Paragraph (h) says explosives of the same compatibility group but different divisions may travel together, with the whole shipment transported as though its entire contents were of the lower numerical division: Division 1.1 is lower than Division 1.2. Paragraph (i) covers one special case: Division 1.5 group D in the same freight container as Division 1.2 group D must travel as Division 1.1 group D.

Detonators get their own rule. Section 177.835(g) bars any detonator assembly or booster with detonator from the same vehicle as Division 1.1, 1.2 or 1.3 material, detonating cord Division 1.4 material or Division 1.5 material, outside three stated exceptions: an MC 201 container, a section 173.62 package with no 1.1, 1.2, 1.3 or 1.5 material on board and 24-inch separation from detonating cord, or a method approved by the Associate Administrator.

What extra bans sit outside the table?

Three bans sit in paragraph (c), in addition to the table. Cyanides, cyanide mixtures or solutions may not be stored, loaded or transported with acids when a mixture of the materials would generate hydrogen cyanide. Division 4.2 materials may not be stored, loaded or transported with Class 8 liquids. Division 6.1 PG I Zone A material may not be stored, loaded or transported with Class 3 material, Class 8 liquids, or Division 4.1, 4.2, 4.3, 5.1 or 5.2 materials.

Two of the three bans duplicate X cells in the table. Division 4.2 with Class 8 liquids is an X cell. Every pair in the Division 6.1 PG I Zone A ban is an X cell. The cyanide ban is different: it turns on the specific materials, not the classes, so no table cell can carry it. A cyanide and an acid can share classes whose table cell is blank and still be banned. The checker carries a checkbox for exactly that case.

Paragraph (c) has one narrow exception, in section 173.12(e), for lab-pack waste. Waste materials packaged under that section are not subject to the segregation table when they are blocked and braced with a minimum horizontal separation of 1.2 meters (4 feet) from incompatible materials and the packages sit at least 100 millimeters (4 inches) off the floor. The vehicle may not contain Class 1 explosives, Class 7 radioactive material or uncontainerized hazardous materials. Waste cyanides and waste acids have per-package quantity limits. Ordinary commercial shipments never qualify.

How do subsidiary hazards change the answer?

A package can carry two hazard labels: a primary hazard and a subsidiary hazard. Paragraph (e)(6) says segregation appropriate to the subsidiary hazard must be applied when that segregation is more restrictive than the segregation required by the primary hazard. The checker tests every combination of primary and subsidiary hazards on both materials and returns the most restrictive cell.

A real example shows why this matters. Class 3 flammable liquids with Class 8 liquids is a blank cell: no restriction. When the Class 3 material also bears a subsidiary Division 6.1 PG I Zone A label, the subsidiary pair is Division 6.1 PG I Zone A with Class 8 liquids, which is an X cell. The load is forbidden. The primary classes alone would never show it. The Hazmat Shipping Paper Checker helps confirm that the subsidiary hazard is entered correctly on the paper before loading.

One exception softens the rule. Hazardous materials of the same class may be stored together without regard to segregation required for any secondary hazard when the materials are not capable of reacting dangerously with each other and causing combustion or dangerous evolution of heat, evolution of flammable, poisonous or asphyxiant gases, or formation of corrosive or unstable materials. That judgment needs knowledge of the specific materials. When in doubt, apply the stricter segregation.

What is the ammonium nitrate exception?

Note A sits in the second column of the segregation table, on the rows for Divisions 1.1 and 1.2, Division 1.5 and Division 5.1. It says that, notwithstanding the X, ammonium nitrate (UN1942) and ammonium nitrate fertilizer may be loaded or stored with Division 1.1 or Division 1.5 materials, unless otherwise prohibited by section 177.835(c).

Read the note narrowly. It names Division 1.1 and Division 1.5 only. Division 1.2 shares a table row with Division 1.1, but Note A does not cover it: ammonium nitrate with Division 1.2 stays forbidden. The note also covers ammonium nitrate and ammonium nitrate fertilizer only. Other oxidizers get no exception. The Division 5.1 row keeps its X against every explosive division for them.

The section 177.835(c) caveat covers Class 1 materials on vehicles in combination. Division 1.1 or 1.2 materials may not be loaded into or carried on a combination that breaks any of its conditions, including combinations with more than two cargo carrying vehicles or with a full trailer under 184 inches of wheel base. The checker flags the caveat on every Note A result. Confirm the combination before loading.

How do you use the Hazmat Segregation Checker?

The checker runs in the browser. Nothing leaves the device. Pick two classes, add subsidiary hazards when the packages carry them, then read the verdict.

  1. Pick the first hazard class or division from the list.
  2. Pick the second hazard class or division from the list.
  3. Add a subsidiary hazard for either material when the package bears a subsidiary hazard label.
  4. Check the cyanide box when one material is a cyanide and the other is an acid. Check the ammonium nitrate box when the Division 5.1 material is ammonium nitrate.
  5. Pick both compatibility groups when the table shows a star for a Class 1 pair.
  6. Read the verdict, the checks and the actions. Fix every failed check before you load.

Before you roll, run the Hazmat Placard Checker for the same load. Segregation and placarding answer different questions. A load can pass one while failing the other.

Frequently asked questions

Can Class 3 flammable liquids ride with Division 5.1 oxidizers?

Only if separated. The segregation table marks Class 3 with Division 5.1 as O. The two materials may ride together only if separated so that, in the event of leakage from packages under conditions normally incident to transportation, commingling of the hazardous materials would not occur. A physical barrier, a separate compartment or enough distance can each pass the test when the leak cannot cross it.

What does the star mean in the hazmat segregation table?

The star means segregation among different Class 1 materials is governed by the compatibility table in 177.848(f). Every Class 1 pair shows a star, so two explosives need their compatibility groups before the answer is known. Pick both groups from the classification codes on the shipping papers, for example 1.1D or 1.4S. Most group pairs may not ride together: 116 of the 169 cells in the compatibility table carry an X.

Can Division 1.1 explosives ride with Division 5.1 oxidizers?

No, with one narrow exception. The table marks Division 5.1 with Division 1.1 as X. Note A lets ammonium nitrate (UN1942) and ammonium nitrate fertilizer load with Division 1.1 or Division 1.5 materials, unless otherwise prohibited by 177.835(c). The exception covers ammonium nitrate only. It covers Division 1.1 and Division 1.5 only. Ammonium nitrate with Division 1.2 stays forbidden. Other oxidizers get no exception.

Do subsidiary hazards affect segregation?

Yes. Section 177.848(e)(6) says segregation appropriate to the subsidiary hazard must be applied when it is more restrictive than the segregation required by the primary hazard. A Class 3 material with a subsidiary Division 6.1 PG I Zone A label cannot ride with Class 8 liquids, even though Class 3 with Class 8 liquids is a blank cell. The checker tests every combination of primary and subsidiary hazards and returns the most restrictive cell.

Can Class 8 liquids ride above Class 4 materials?

No. Section 177.848(e)(3) says Class 8 liquids may not be loaded above or adjacent to Class 4 or Class 5 materials, notwithstanding the methods of separation employed. The one exception is a truckload shipment where the shipper knows the mixture of contents would not cause a fire or a dangerous evolution of heat or gas. The rule covers Division 4.1, Division 4.3, Division 5.1 and Division 5.2. Division 4.2 with Class 8 liquids is an X pair, so the question never arises for it.

What happens when a class is not in the segregation table?

No restriction applies under the table. Section 177.848(e)(1) says the absence of a hazard class or division from the table means no restriction applies. Division 6.1 appears only as PG I Zone A liquids, so other Division 6.1 materials are not listed. Class 8 appears only as liquids, so corrosive solids are not listed. That reading covers the table only: carrier policy, shipper instructions or another rule can still bar a combination.